Red-D-Arc RDA150T3 Service Manual Download Page 18

 

 

 

It

e

ms

 

Article 

Method 

Condition to verify 

Criterion 

In

s

u

la

ti

o

n

 

C

h

e

c

k

 

Dielectric Voltage 

Tester 

Connect “grounding terminal” 

- with output terminal “L1”. 
- with output terminal “L2”   
- with output terminal “L3”. 
- with initial excitation winding. 
(Coupler marked with “J” or “K”.) 

ditto 

M

o

n

it

o

Glow & Monitor Lamp 

(OIL PRESS, 

WATER TEMP, 

ENGINE, AIR 

FILTER & FUEL) 

Visual 

Inspection 

Starter Switch 

“RUN” 

position 

Coolant Temp:-15~50

  (5~122

°

F ) 

Glow  Lamp  &  Charge  Lamp  ON.  DIAG  (diagnosis)  lamp 
OFF after it turns on for a while. Hour Meter is activated. 

Engine is 

running. 

All  monitor  lamp  OFF.  Pilot  lamp  ON.  Hour  meter  is 
activated. 

Pro

te

c

ti

o

n

 C

irc

u

it

 

Emergency Stop 

Engine is 

running 

Emergency stop switch ON and engine stops. 

Water Temp. 

Short-circuit  red/black  and  black/yellow  lines  connecting 
to  a  water  temp.  sensor.  Overheat  lamp  ON  and  engine 
stops. 

Thermal Relay 

Engine Stop 

Thermal  relay  is  set  at  3.6A.  Breaker  ON  and  thermal 
relay RESET. 

Engine is 

running 

Turn  test  trip  lever  to  “TRIP”.  Main  breaker  lever  trips 
between ON and OFF position. 

Terminal Cover 

Safety Feature 

Open  3-Phase  output  terminal  cover.  Main  breaker  lever 
trips between ON and OFF position.   

O

p

e

ra

ti

o

n

a

C

h

e

c

k

 

Phase rotation 

Phase 

Rotation 

Indicator 

 

Rotate as arrow shows   

AVR Adjustment 

AC Volt 

Meter 

Output selector switch is 
set at 2080V (3-phase) 

No Load 

Voltage Adj. Dial: Max 

Frequency (Hz) 

Output (V) 

60

±

0.1 

253

±1

 

*Adjust  the  Volt  Adjusting 
Volume in AVR. (

#1

)

 

3-Phase Output 

(Comprehensive 

Voltage Regulation) 

Load Tester 

Frequency 

Meter 

Wattmeter 

Stop Watch 

Engine Speed 1800

 min

-1,

 

Engine Control Switch Setting: 

Load Advance: OFF 

- Regulation Mode: OFF: 

Output selector switch is 
set at 480V. (3-phase) 
Output: 120

±1.2kW 

Voltage: 480+/-1V 
Frequency: 60

±0.1Hz

 

Power Factor: 1.0 
Throttle Switch: RUN 

kW 

Hz 

100 

120+/-1.2 

480±1 

(1.04) 

60

±0.1 

75 

90+/-0.9 

480±6 

(0.88) 

60±0.2 

50 

60+/-0.6 

(0.72) 

25 

30+/-0.3 

(0.60) 

no load 

(0.57) 

3-Phase Output 
(Transient Load 

Change Excursions) 

Output selector switch is 
set at 280V. (3-phase) 
Output: 120±1.2kW 
Voltage: 240+/-1V   
Power Factor: 1.0 
Throttle Switch: RUN 

Refer to 

#2

 

1-Phase Output 

AC Volt 

Meter 

Output selector switch is 
set at 240/120V. 
(3-phase) 
Voltage: 240+/-1V 
Frequency: 60±0.1Hz 

No 

Load 

Receptacle 

Voltage (50A) X-Y 

240±3V 

GFCI Receptacle 

Output 

120±2V 

3-Phase Output 
Voltage Adjustment 

Output  selector  switch  is 
set at 480V. (3-Phase)   

Voltage Max. (V) 

Voltage Min. (V) 

over 504 

below 408 

Engine Speed 
Adjustment 

Digital 

Tachometer 

Adjust  the  engine  control 
switch at no load. 

Idle Speed 

(min-1)

 

Engine Speed 

Adjustment (Hz) 

1000

±

25 

below 50~above 63. 

 
 

15 

Summary of Contents for RDA150T3

Page 1: ...urself with its contents for your safety This equipment should only be operated and maintained by trained and qualified personnel This equipment is designed for generating power source of electric too...

Page 2: ...ormation contained in this service manual describes equipment available at the time of publication While every attempt has been made to give you the very latest information about your product there ma...

Page 3: ...General 5 4 1 Appearance 5 4 2 Dimension 5 5 General Parts Description 7 5 1 Equipment 7 5 2 Main Parts and Feature 10 5 3 Main Component 10 6 Service Data 13 6 1 Service Data 13 6 2 Generator 14 7 T...

Page 4: ...ice and maintenance of the equipment for understanding of the equipment safety instructions and cautions Throughout this manual are special attention statements A statement preceded by the triangular...

Page 5: ...nt is used in poorly ventilated area such as inside of the building Entangled Injuries under By Moving Component NEVER reach and touch the moving component during operation ALWAYS stop the engine duri...

Page 6: ...e Before replacing the label s make sure to place the new label s in the same position STOP the equipment immediately when abnormal circumstances are noticed STSTOP the equipment immediately whenever...

Page 7: ...UZU No of Cylinders bore x stroke in mm 6 4 53x4 92 115x125 Continuous rated output kW 142 HP 190 Rated speed rpm 1800 Displacement cu in liters 475 4 7 790 Combustion system Direct Fuel Injection wit...

Page 8: ...4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm 5...

Page 9: ...6...

Page 10: ...5 General Parts Description 5 1 Equipment 7...

Page 11: ...8...

Page 12: ...9...

Page 13: ...ht a monitor lamp when equipment is malfunctioned Volt Meter Selector Dial Feature Dial to change voltage Water Temp Meter Feature Display water temp in the radiator Fuel Meter Feature Display volume...

Page 14: ...output from the alternator 11 Fuel Drain Plug Feature Drain the old fuel from the fuel tank Oil Drain Plug Feature Drain the old oil from the oil tank External Fuel Inlet Feature Inlet to refuel from...

Page 15: ...nal fuel tank Position B to use an external fuel tank Position the 3 way valve lever to DOWNWARD to use fuel from a built in fuel tank Note The 3 way valve lever is set at position A at delivery from...

Page 16: ...Max rpm at no load 60Hz 1800 25 min 1 Lubricant oil pressure 0 2 0 6MPa 2 0 6 1kgf cm Coolant temperature 75 90 167 194 F Frame temperature limit within 115 239 F Sealed bearing temperature limit with...

Page 17: ...ns Items Article Method Condition to verify Criterion Check before operation Shape Dent Blot Visual Inspection No dent blot and deformation Coating No looseness Joint Meet the criteria Oil Coolant Mee...

Page 18: ...Phase rotation Phase Rotation Indicator Rotate as arrow shows AVR Adjustment AC Volt Meter Output selector switch is set at 2080V 3 phase No Load Voltage Adj Dial Max Frequency Hz Output V 60 0 1 253...

Page 19: ...d No Load Transient Max below 288 below 2 sec below 66 below 8 sec No Load 240 3 60 0 2 No Load Loaded Transient Min over 192 below 2 sec over 54 below 8 Loaded 240 3 60 0 2 Use screw locking glue rec...

Page 20: ...0 Radiator Frame Bolt M12x50 4 20 8 30 4 213 309 Uniformly tighten the bolts 11 Exhaust Pipe Engine Nut M10 fine pitch 8 30 5 45 1 312 459 12 Flex Tube Exhaust Pipe Bolt M16x65 4 122 6 181 4 1251 1849...

Page 21: ...ence 20 Joint Engine Joint G3 4 2 54 2 63 9 553 651 ditto 21 Hose 14 Joint Hose 14 G3 4 2 107 9 127 4 1101 1299 Attention to piping for inlet outlet 22 Air Cleaner Cleaner Band Attention to the direct...

Page 22: ...e fuel filter and water sedimenter Clean Clean or replace fuel filter element and water sedimenter element Clean Replace Drain water from fuel tank Clean gauze filter in engine feed pump Clean Change...

Page 23: ...r distributor to repair Ambient temperature falls down below zero 1 Fuel is frozen 2 Water in fuel line is frozen 3 Pre heater is defective 1 Use winterized fuel 2 Drain water in fuel line 3 Contact y...

Page 24: ...lector switch set is wrong 1 Contact your distributor to repair 2 Contact your distributor to repair 3 Contact your distributor to repair 4 Contact your distributor to repair 5 Correctly set the conne...

Page 25: ...10 Wiring Diagram 22...

Page 26: ...23...

Page 27: ...Call us toll free at 1 866 733 3272 US and Canada reddarc com...