Red-D-Arc RDA150T3 Service Manual Download Page 5

 

2

 

2. General Safety Instructions

 

 
 

 

ELECTRIC SHOCK 

NEVER

 touch the output terminals 

during operation

 

NEVER

 touch the output terminal during 

operation even though the breaker on the 

load is being set at “OFF” position.

   

 

ALWAYS 

stop engine and make sure it 

stopped before you will connect the loads to 

the output terminals.

   

 

Suffocation  by  exhaust gas

 

 

NEVER run the engine indoors! Make 

sure there is always good ventilation. 

Fumes from engine exhaust cause 

serious injury.

 

 

ALWAYS 

operate the equipment in the 

ventilated area. 

When the equipment is used in a tunnel, hall 

or any other indoor, the equipment for 

ventilation must be used to prevent serious 

accident caused by suffocation.   

 

NEVER

 direct the exhaust fume to 

houses nearby while considering the wind 

flow direction.   

Exhaust gas contains many harmful 

elements that would cause affect to human. 

Be free from suffocation when the 

equipment is used in poorly ventilated area 

such as inside of the building. 

 
 

 
 

 

Entangled Injuries under 

By      Moving Componen

 

NEVER

 reach and touch the moving 

component during operation!

 

 

ALWAYS

 stop the engine during inspection 

to prevent serious bodily injury by entangled 

accident under moving component.

 

 

Electric shock/Injuries/Burns 

 

 

Never

 inspect equipment during 

use

.

 

Never

 serve and inspect when equipment is 

being operated. 

It may cause electric shock, injuries or 

burns.

 

 

 

WARNING-Use good judgment

 

 

NEVER

 run the engine when 

transporting the equipment. 

 

ALWAYS 

stop the equipment 

immediately if it suddenly begins to 

violate or abnormal noise. Inspect for 

broken, missing or improperly installed 

parts.

 

 

ALWAYS

 keep the equipment as clean 

as practical. Keep it free of loose 

vegetation, mud, etc.

 

 

DO NOT

 make unauthorized 

modifications or alterations to this equipment 

of any of its components. YAMABIKO must 

authorize alterations and modifications in 

writing. Unauthorized modifications or 

alterations may alter the equipment 

operation and could jeopardize personal 

safety during operation.

 

WARNING

 

   

Summary of Contents for RDA150T3

Page 1: ...urself with its contents for your safety This equipment should only be operated and maintained by trained and qualified personnel This equipment is designed for generating power source of electric too...

Page 2: ...ormation contained in this service manual describes equipment available at the time of publication While every attempt has been made to give you the very latest information about your product there ma...

Page 3: ...General 5 4 1 Appearance 5 4 2 Dimension 5 5 General Parts Description 7 5 1 Equipment 7 5 2 Main Parts and Feature 10 5 3 Main Component 10 6 Service Data 13 6 1 Service Data 13 6 2 Generator 14 7 T...

Page 4: ...ice and maintenance of the equipment for understanding of the equipment safety instructions and cautions Throughout this manual are special attention statements A statement preceded by the triangular...

Page 5: ...nt is used in poorly ventilated area such as inside of the building Entangled Injuries under By Moving Component NEVER reach and touch the moving component during operation ALWAYS stop the engine duri...

Page 6: ...e Before replacing the label s make sure to place the new label s in the same position STOP the equipment immediately when abnormal circumstances are noticed STSTOP the equipment immediately whenever...

Page 7: ...UZU No of Cylinders bore x stroke in mm 6 4 53x4 92 115x125 Continuous rated output kW 142 HP 190 Rated speed rpm 1800 Displacement cu in liters 475 4 7 790 Combustion system Direct Fuel Injection wit...

Page 8: ...4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm 5...

Page 9: ...6...

Page 10: ...5 General Parts Description 5 1 Equipment 7...

Page 11: ...8...

Page 12: ...9...

Page 13: ...ht a monitor lamp when equipment is malfunctioned Volt Meter Selector Dial Feature Dial to change voltage Water Temp Meter Feature Display water temp in the radiator Fuel Meter Feature Display volume...

Page 14: ...output from the alternator 11 Fuel Drain Plug Feature Drain the old fuel from the fuel tank Oil Drain Plug Feature Drain the old oil from the oil tank External Fuel Inlet Feature Inlet to refuel from...

Page 15: ...nal fuel tank Position B to use an external fuel tank Position the 3 way valve lever to DOWNWARD to use fuel from a built in fuel tank Note The 3 way valve lever is set at position A at delivery from...

Page 16: ...Max rpm at no load 60Hz 1800 25 min 1 Lubricant oil pressure 0 2 0 6MPa 2 0 6 1kgf cm Coolant temperature 75 90 167 194 F Frame temperature limit within 115 239 F Sealed bearing temperature limit with...

Page 17: ...ns Items Article Method Condition to verify Criterion Check before operation Shape Dent Blot Visual Inspection No dent blot and deformation Coating No looseness Joint Meet the criteria Oil Coolant Mee...

Page 18: ...Phase rotation Phase Rotation Indicator Rotate as arrow shows AVR Adjustment AC Volt Meter Output selector switch is set at 2080V 3 phase No Load Voltage Adj Dial Max Frequency Hz Output V 60 0 1 253...

Page 19: ...d No Load Transient Max below 288 below 2 sec below 66 below 8 sec No Load 240 3 60 0 2 No Load Loaded Transient Min over 192 below 2 sec over 54 below 8 Loaded 240 3 60 0 2 Use screw locking glue rec...

Page 20: ...0 Radiator Frame Bolt M12x50 4 20 8 30 4 213 309 Uniformly tighten the bolts 11 Exhaust Pipe Engine Nut M10 fine pitch 8 30 5 45 1 312 459 12 Flex Tube Exhaust Pipe Bolt M16x65 4 122 6 181 4 1251 1849...

Page 21: ...ence 20 Joint Engine Joint G3 4 2 54 2 63 9 553 651 ditto 21 Hose 14 Joint Hose 14 G3 4 2 107 9 127 4 1101 1299 Attention to piping for inlet outlet 22 Air Cleaner Cleaner Band Attention to the direct...

Page 22: ...e fuel filter and water sedimenter Clean Clean or replace fuel filter element and water sedimenter element Clean Replace Drain water from fuel tank Clean gauze filter in engine feed pump Clean Change...

Page 23: ...r distributor to repair Ambient temperature falls down below zero 1 Fuel is frozen 2 Water in fuel line is frozen 3 Pre heater is defective 1 Use winterized fuel 2 Drain water in fuel line 3 Contact y...

Page 24: ...lector switch set is wrong 1 Contact your distributor to repair 2 Contact your distributor to repair 3 Contact your distributor to repair 4 Contact your distributor to repair 5 Correctly set the conne...

Page 25: ...10 Wiring Diagram 22...

Page 26: ...23...

Page 27: ...Call us toll free at 1 866 733 3272 US and Canada reddarc com...

Reviews: