6. Service Data
ELECTRIC SHOCK
WARNING
Never touch the output terminal during operation to avoid electric
shock. Always stop the engine and remove the starter key during a
service maintenance.
Stop the engine before you will start any maintenance!
6-1 Technical Specification
Items
Reference Value
Note
Insulation
Armature
winding
3MΩ or more
DC500V
Megger Tester
Exciter field
Preheat time
Approx. 20 sec. with coolant temperature
-15
℃
(5
°
F)
and approx. 1 sec. with coolant
temperature 30
℃
(86
°
F)
Automatic
preheating system
Min. rpm at no load
1000
±
25 min
-1
Max. rpm at no load
60Hz: 1800
±
25 min
-1
Lubricant oil pressure
0.2~0.6MPa{2.0~6.1kgf/cm²}
Coolant temperature
75~90
℃
(167~194
°
F)
Frame temperature limit
within 115
℃
(239
°
F)
Sealed bearing temperature limit
within 70
℃
(158
°
F)
Speed regulation
Momentary
within 10%
Steady-state
deviation
within 5%
Voltage regulation
Momentary
within 20%
Steady-state
deviation
within 1.0%
Frequency
Idle: 33.3 Hz, Rated: 60 Hz
Variable voltage (60Hz)
400~505V
at 60
±
0.1Hz
Protective device
1
Low oil pressure
Working Pressure
0.1MPa{1.02kgf/cm²}
Engine Stop
2
High water temp.
Working Temperature
105
℃
(221
°
F)
Engine Stop
3
Diagnosis
Engine Malfunction
-
-
4
Insufficient Battery
Charge
-
Battery voltage: below 8V
-
5
Over Speed
-
above 2070 min
-1
Engine Stop
6
Boost
Intake Temperature
85
℃
(185
°
F)
-
13
Summary of Contents for RDA150T3
Page 8: ...4 General 4 1 Appearance 4 2 Dimension Unit in the drawings below is shows by mm 5...
Page 9: ...6...
Page 10: ...5 General Parts Description 5 1 Equipment 7...
Page 11: ...8...
Page 12: ...9...
Page 25: ...10 Wiring Diagram 22...
Page 26: ...23...
Page 27: ...Call us toll free at 1 866 733 3272 US and Canada reddarc com...