Functions and safety check
9
BAL_SYS20_RED_EN_2V2_REC_102-020110693
25/ 27
Monthly inspection work to be carried out by the operating company
The monthly inspection and maintenance of individual elements by the operating company requires
little time and serves the reliable function, increased service life and operational safety of the system.
Test / inspection
Procedure
Expected result
Motion detector
▪ Approach the door at normal
speed (from the inside and
outside)
▪ If necessary, clean the sen-
sors (motion detectors), in
particular the external sen-
sor(s)
▪ Note that steaming up of the
sensor, for instance due to
warm, moist indoor air escap-
ing and condensing on the
colder external motion sen-
sor, can prevent the door
from closing. Therefore, en-
sure that the indoor air is de-
humidified or wipe the exter-
nal sensor dry if necessary.
▪ The sensor must cover the
entire passage width
▪ The door is opened early and
at an adequate speed to al-
low an unimpeded passage
Door wings / side parts
▪ Check the condition of the
panes
▪ Check the condition of the
gaskets / profiles
▪ No damaged panes
▪ No torn out gaskets (energy
loss)
▪ The door is the "business
card" of your company.
Therefore make sure that the
door is in perfect condition
Door leaf guides
▪ Check the door leaf guides
▪ These may have been dam-
aged by impacts (e.g. by
shopping trolleys)
▪ Intensive use and exposure
to dirt can lead to extraordi-
nary wear and tear on door
leaf guides
▪ The door leaf must be
properly guided
▪ Bottom and vertical door
profiles exhibit no scratch
marks
▪ The door leaf guide must not
generate any unusual noises
during opening/closing
9.2