Maintenance and regular inspection
Prior to carrying out the first commissioning and if required as well as in accordance with the applica-
ble regulations - however at least twice a year – a technical inspection by a skilled service technician
or an authorized partner must take place. We recommend performing maintenance at the same time.
Any due maintenance is indicated on the display of the BDE-D control unit. The interval for the edition
of this message is determined by the number of opening cycles and/or the expiry of a defined operat-
ing period.
Regular maintenance and inspection of the automatic door by trained personnel authorized by the
manufacturer provides the best guarantee for a long service life and an error-free operation.
We recommend the conclusion of a service contract with the respective service department in your
region.
IMPORTANT
A listing of recommended spare parts is supplied in the annex and is also availa-
ble on request at your service department.
Operator duties
According to principles for inspecting automatic door systems, in particular according to case law of
safety obligations, automatic door systems must be inspected by a qualified technician before com-
missioning and thereafter according to the manufacturer recommendation. It is particularly important
for the protection of people, to observe and to comply with the requirements for public access facili-
ties! The operator is responsible to fulfill the duties required for the door system.
Task
To be conducted by
Time of implementation Entry in log book re-
quired
Final inspection
Technical expert
After ready for use in-
stallation of the door
system
Yes
Maintenance and clean-
ing
especially of the sensors
for protection and trip-
ping
Operator
Weekly or if required
No
CAUTION
Sensors for protection and tripping must be kept free from contamination and
fogging in order to avoid malfunctioning of the system.