Original Instruction Manual |
WG250
Wet Stone Sharpening System | Version 3.0 | November 2012
34
Changing the Sharpening Stone
If the sharpening stone (C) is worn down to a diameter of
approximately 150mm it needs to be replaced.
1. Disconnect the WG250 from the power source.
2. Loosen the Nut (M) and remove the old
sharpening Stone.
Changing the honing wheel
1. Disconnect the WG250 from the power source.
2. Loosen the lock knob (N) and remove the worn honing
wheel.
3. Install the new leather honing wheel (A)
4. Pay attention that the 3 drive pins engage with the
friction drive wheel (O).
5. If the leather strop wheel seems to wobble, please try
rotating it to the next pin location.
6. Tighten the lock knob (N)
11. Maintenance - Cont.
A
B
C
D
E
F
G
J
C
M
K
L
N
A
O
P
Q
R
S
T
I
H
A
B
C
D
E
F
G
J
C
M
K
L
N
A
O
P
Q
R
S
T
I
H
Note:
That the lock nut (M) has a left hand thread i.e. turn
clockwise to loosen, turn anti-clockwise to tighten.
3. The new Sharpening Stone has to meet the correct
technical specification. Always use a genuine
replacement stone.
4. Check abrasive wheel for flaws (e.g. cracks) before
installation. Do not use faulty wheels.
5. Install the new Sharpening Stone (C).
6. Place a washer (L) on each sides of the sharpening stone
and tighten the nut (M).
Summary of Contents for WG250