Beijing Reci Laser Technology Co., Ltd
User Guide for FSC1000, FSC1500
38
NO
MESSAGE
DESCRIPTION
SOLUTION
4
“PumpTemp”
fault
The temperature at the
pump
Laser
source
exceeds the temperature
limit.
Check whether the water cooler is working
properly and whether the water temperature is
set correctly. When the water cooler works
normally and the water temperature drops to
the set temperature, restart the laser source. If
there is any trouble, please contact our
after-sales service staff.
5
IntergHard
fault
Laser
internal
optical
path detection failure
Contact our after-sales service personnel to
see if you can continue to use lasers.(
This
function is generally idle)
6
WaterTemp
fault
The
laser
water
temperature is too high
or the water flow is
below the set value.
Check that the water pipe is installed
correctly, check the chiller is working
properly and ensure the water flow meets the
requirements.
7
PrevBurn
fault
Laser
internal
optical
path detection failure
Contact our after-sales service personnel to
see if you can continue to use lasers.
8
CurHard
fault
The laser module supply
current
exceeds
the
hardware threshold.
Check if the 220V power supply of the laser
is stable. If it is stable, reduce the peak output
power of the laser. If it still occurs, please
contact our after-sales service personnel.
9
IdleCur
fault
The current value when
the laser is turned off
exceeds the upper limit.
Restart the laser. If it happens frequently,
please
contact
our
after-sales
service
personnel.
10
WaterFlow
fault
The water flow is below
the set value
The FSC1000&FSC1500 series lasers have
omitted this function.
11
Cooling
fault
Laser
internal
optical
path detection failure.
Most of time, caused by
Lack of cooling.
Contact our after-sales service personnel to
see if you can continue to use lasers.
12
TrialExpi
fault
Trial time limit exceeded
Contact our after-sales service personnel to