TECHNICAL PROPERTIES: REC ALPHA PURE-R SERIES 

Ref: PM-

DS-12-06-

Rev- A 

04.22

www.recgroup.com

GR

GR

GR

GR

GR

11±0.2

6.6±0.2

20.5±0.5

6.0±0.2

1700

1700

1730±2.5

880

425

1077±2.5 

22.5

594±3

1118±2.5

17

45 

30

38

GENERAL DATA

Cell type:

80 half-cut REC heterojunction cells with 

lead-free, gapless technology

Glass:

3.2 mm solar glass with anti-refl ective surface treatment

in accordance with EN 12150

Backsheet:

Highly resistant polymer (black)

Frame:

Anodized aluminum (black)

Junction box:

4-part, 4 bypass diodes, lead-free

 

IP68 rated, in accordance with IEC 62790 

Connectors:

Stäubli MC4 PV-KBT4/KST4 (4 mm²)

in accordance with IEC 62852, IP68 only when connected

Cable:

4 mm² solar cable, 1.7 + 1.7 m

in accordance with EN 50618

Dimensions:

1730 x 1118 x 30 mm (1.93 m

2

)

Weight:

21.5 kg

Origin:

Made in Singapore

Specifications subject to change without notice.

Measurements in mm

LOW LIGHT BEHAVIOUR

Typical low irradiance performance of module at STC:

WARRANTY

Standard

REC ProTrust

Installed by an REC 

Certifi ed Solar Professional

No

Yes

Yes

System Size 

All

≤25 kW 25-500 kW

Product Warranty (yrs)

20

25

25

Power Warranty (yrs)

25

25

25

Labor Warranty (yrs)

0

25

10

Power in Year 1

98%

98%

98%

Annual Degradation

0.25% 0.25%

0.25%

Power in Year 25

92%

92%

92%

See warranty documents for details. Conditions apply 

Irradiance (W/m²)

Rel. Effi

  ciency (%)

TEMPERATURE RATINGS

*

Nominal Module Operating Temperature:

44°C (±2°C)

Temperature coeffi  cient of P

MAX

:

-0.26 %/°C

Temperature coeffi  cient of V

OC

:

-0.24 %/°C

Temperature coeffi  cient of I

SC

:

0.04 %/°C

*

The temperature coeffi  cients stated are linear values

CERTIFICATIONS

IEC 61215:2016, IEC 61730:2016, UL 61730
IEC 61215-2:2016

Hailstone (35mm)

IEC 61730-2:2016

Fire Class C (as per UL790)

IEC 62321

Lead-free

 

acc. to RoHS EU 863/2015

ISO 14001, ISO 9001, IEC 45001, IEC 62941

MAXIMUM RATINGS

Operational temperature:

-40 ... +85°C

System voltage:

1000 V

Test load (front):

 + 7000 Pa (713 kg/m²)

*

Test load (rear):

- 3000 Pa (305 kg/m²)

*

Series fuse rating:

25 A

Reverse current:

25 A

*

 See installation manual for mounting instructions.

Design load = Test load / 1.5 (safety factor)

 S

TC

 N

M

O

T

Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, aff ordable solar power. As 

Solar’s Most Trusted, REC is committ ed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. 

Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacifi c.

85

90

95

100

105

200

100

300

400

500

600

700

800

900

1000

REC Alpha PURE-R Series

Product SPECIFICATIONS

take-e-way WEEE-compliant 

recycling scheme

Lead-Free

ELECTRICAL DATA

Product Code

*

: RECxxxAA Pure-R

Power Output - P

MAX

 (Wp) 

400

410

420

430

Watt  Class Sorting - (W)

0/+10

0/+10

0/+10

0/+10

Nominal Power Voltage - V

MPP

 (V) 

48.8

49.4

50.0

50.5

Nominal Power Current - I

MPP

 (A) 

8.20

8.30

8.40

8.52

Open Circuit Voltage - V

OC

 (V) 

58.9

59.2

59.4

59.7

Short Circuit Current - I

SC

 (A) 

8.73

8.81

8.89

8.97

Power Density (W/m

2

)

207

212

218

223

Panel Effi  ciency (%) 

20.7

21.2

21.8

22.3

Power Output - P

MAX

 (Wp)

305

312

320

327

Nominal Power Voltage - V

MPP

 (V) 

46.0

46.6

47.1

47.6

Nominal Power Current - I

MPP

 (A) 

6.64

6.70

6.78

6.88

Open Circuit Voltage - V

OC

 (V) 

55.5

55.8

56.0

56.3

Short Circuit Current - I

SC

 (A) 

7.05

7.12

7.18

7.24

Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C), based on a production spread with a 

tolerance of P

MAX

, V

OC 

& I

SC

 ±3% within one watt  class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², 

temperature 20°C, windspeed 1 m/s). * Where xxx indicates the nominal power class (P

MAX

) at STC above.

DELIVERY INFORMATION

Panels per pallet:

33

Panels per 40 ft  GP/high cube container:

858 (26 pallets)

Panels per 13.6 m truck:

924 (28 pallets)

Available from:

Fig. 18: Panel dimensions: REC Alpha Pure-R Series

Summary of Contents for Alpha Pure Series

Page 1: ...FOR ALL REC ALPHA SOLAR PANELS CERTIFIED ACCORDINGTO IEC 61215 IEC 61730 STANDARDS rec Alph panels Installation Manual REC Alpha Pure Series REC Alpha Pure R Series Rev 13 11 22...

Page 2: ...ure Series panels with short rails 11 Installation of REC Alpha Pure R Series panels 12 Mounting with continous rails parallel to short side of the panel 12 Mounting REC Alpha Pure R Series panels wit...

Page 3: ...o short side of the panel 12 Fig 7 Clamping of REC Alpha Pure R Series panels with rails parallel to long side of the panel 13 Fig 8 Clamping of REC Alpha Pure R Series panels using short rails 14 Fig...

Page 4: ...nly qualified personnel must perform work on photovoltaic systems such as installation commissioning maintenance and repairs Be sure to follow the safety instructions for all system components Ensurin...

Page 5: ...served during handling to avoid the risk of sparking fire hazards burns and lethal electric shocks Exercise extreme caution when wiring panels and look out for damaged or dirty cables etc Never insert...

Page 6: ...rdegradationtothepackagingorpanelcomponents pallets and panels must be stored in a controlled environment ideally internal where it is protected from the elements e g rain dust and direct sunlight If...

Page 7: ...age Voc and short circuit current Isc deviate from specification this may indicate a configuration fault Correct DC polarity must be observed at all times Electrical Ratings Electricalratingsarewithin...

Page 8: ...o the manufacturer s instructions including specific hardware and torque requirements Ensure the clamps used are suitable for the planned installation and expected system design loads The grip area mu...

Page 9: ...Pa 2400Pa 2400Pa 1600Pa 1600Pa X 255 375 mm 1800Pa 1800Pa 1200Pa 1200Pa 4200Pa 2400Pa 2800Pa 1600Pa 5400Pa 2400Pa 3600Pa 1600Pa X 375 505 mm 1800Pa 1800Pa 1200Pa 1200Pa 6200Pa 4000Pa 4133Pa 2666Pa 700...

Page 10: ...PANELS WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE PANEL A continous rail or other support structure spans the complete underside of the panel Legend Clearance Gap Clamping zone 20 40 mm 40 60 m...

Page 11: ...2400Pa 3000Pa 1600Pa X 375 505 mm 1200Pa 1200Pa 800Pa 800Pa 3000Pa 3000Pa 2000Pa 2000Pa 4200Pa 4000Pa 2800Pa 2666Pa X 505 610 mm 1200Pa 1200Pa 800Pa 800Pa 2400Pa 2400Pa 1600Pa 1600Pa 3600Pa 2400Pa 240...

Page 12: ...800Pa 1800Pa 1200Pa 1200Pa 6200Pa 3000Pa 4133Pa 2000Pa 7000Pa 3000Pa 4666Pa 2000Pa 520 570 mm 1200Pa 1200Pa 800Pa 800Pa 3000Pa 2400Pa 2000Pa 1600Pa 5400Pa 2400Pa 3600Pa 1600Pa 570 730 mm 2400Pa 2400Pa...

Page 13: ...other support structure spans the complete underside of the panel Legend Clearance Gap Clamping zone 20 40 mm 40 60 mm 60 mm Test Load DesignLoad Test Load DesignLoad Test Load DesignLoad 90 730 mm 1...

Page 14: ...0Pa 800Pa 2400Pa 2400Pa 1600Pa 1600Pa 3600Pa 2400Pa 2400Pa 1600Pa 570 730 mm 1200Pa 1200Pa 800Pa 800Pa 1600Pa 1600Pa 1066Pa 1066Pa 2400Pa 2400Pa 1600Pa 1600Pa 0 200 mm X 800Pa 800Pa 533Pa 533Pa 800Pa...

Page 15: ...apply a safety factor of 1 5 to the stated test load e g test load 5400 Pa 1 5 3600 Pa design load Part Name Material Rail 6105 T5 aluminum extrusion Bolt M6 x 25 drop inT stud kit Nut M6 flanged hex...

Page 16: ...pport structures must be used to secure the panel The center point of each clamp and the minimum grip length must be fully located within the marked zone to be rated to the given value fig 12 Legend C...

Page 17: ...used to secure the panel The center point of each clamp and the minimum grip length must be fully located within the marked zone to be rated to the given value fig 13 Legend Clearance Gap Clamping zo...

Page 18: ...t side as shown in fig 12 and can be further identified by the grounding symbol stamped in the frame next to it Check all applicable requirements before beginning installation Suitable grounding clips...

Page 19: ...coveranyfaulttraceabletothereplacedconnectors Anyothermodificationtothepanelisprohibited includingthe openingofthejunctionbox unlessexplicitlyauthorizedbyREC Doingsowillinvalidatethewarranty CABLEMANA...

Page 20: ...ng to local guidelines and regulations By ensuring REC solar panels are disposed of correctly you will help prevent any negative impact on the environment and human health The majority of the panel co...

Page 21: ...0 04 C The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215 2016 IEC 61730 2016 UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance ISO 11925 2 Ignitabili...

Page 22: ...IMUM RATINGS Operational temperature 40 85 C System voltage 1000V Test load front 7000Pa 713 kg m Test load rear 3000Pa 305 kg m Series fuse rating 25A Reverse current 25A See installation manual for...

Page 23: ...slack to prevent damage due to water level changes and wave motions ii Mounting panels Installation of REC solar panels must be in accordance with the aforementioned standard mounting instructions Th...

Page 24: ...n MLPE device directly to the solar panel frame follow the MLPE manufacturer s instructions to ensure optimum mounting of the device and prevent any slippage during operation WheninstallinganMLPEdevic...

Page 25: ...of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits The technical documentation and full compliance...

Page 26: ...tage limits The technical documentation and full compliance with the standards listed below proves the conformity of the product with the requirements of and conformity with the Electrical Equipment S...

Page 27: ...ddition of REC Alpha 72 Series 03 2021 6 Updated Datasheets 06 2021 7 Addition of REC Alpha Pure Series 11 2021 8 Updated Datasheets 03 2022 9 Added six point clamping and added requirement for washer...

Page 28: ...RECSOLARPTE LTD 20TUASSOUTHAVENUE14 SINGAPORE637312 SINGAPORE Tel 6564959228 Mail post recgroup com www recgroup com...

Reviews: