REC Installation Manual - REC Alpha Panels - IEC 61215 /61730
Rev 13 - 11.22
13
730 mm
300 mm
200 mm
0
0
300 mm
200 mm
0
300 mm
200 mm
0
300 mm
200 mm
0
0
730 mm
90 mm
90 mm
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated to that load (fig. 7).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
Rail positioning
Rail positioning
Fig. 7: Clamping of REC Alpha Pure-R Series panels with rails parallel to long side of the panel
Rail position
Rail position
MOUNTING REC ALPHA PURE-R SERIES PANELS WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE PANEL
A continous rail (or other support structure) spans the complete underside of the panel.
Legend
Clearance Gap
Clamping zone
20-40 mm
40-60 mm
>60 mm
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
90 - 730 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
0 - 200 mm
X
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
200 - 300 mm
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
Installations with a clearance gap between the uppermost part of the roof and lowest part of the panel (i.e., frame) with a clearance
gap of <20 mm are not permitted.
Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5, may be freely located on panel frame without
affecting the warranty. Loads marked with a
*
were not certified as part of IEC 61215/61730 testing; these have been evaluated by
REC’s internal testing process.