background image

                                                                                                                                                                          Ameba-D Application Note 

 Application Note                                                                                                                  All information provided in this document is subject to legal disclaimers.                                                            © REALTEK 2020. All rights reserved.

 

23 

cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one of the following measures: 
 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that 

to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 
 

FCC Caution:

 Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to 

operate this equipment. 
 

IMPORTANT NOTE: 

FCC Radiation Exposure Statement: 
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 
operated with minimum distance 20cm between the radiator & your body. 
 
This  device  and  its  antenna(s) must not  be  co-located  with  any  other  transmitters  except  in accordance with  FCC  multi-transmitter product 
procedures. 
Refering to the multi-transmitter policy, multiple-transmitter(s) and module(s) can be operated simultaneously without C2PC.  
 
This module is intended for OEM integrator. The OEM integrator is responsible for the compliance to all the rules that apply to the product into 
which this certified RF module is integrated. 
Additional testing and certification may be necessary when multiple modules are used. 
 

List of applicable FCC rules 

This module has been tested and found to comply with part 22, part 24, part 27, 15.247 and 15.407 requirements for Modular Approval. 
The  modular transmitter  is  only  FCC  authorized for  the  specific  rule  parts  (i.e., FCC  transmitter  rules)  listed  on the  grant,  and  that  the host 
product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant 
of certification. If the grantee markets their product as being Part 15 Subpart B compliant (when it also contains unintentional-radiator digital 
circuity), then the grantee shall provide a notice stating that the final host product still requires Part 15 Subpart B compliance testing with the 
modular transmitter installed. 
 

USERS MANUAL OF THE END PRODUCT: 

In the  users manual of the end product, the end user has  to be informed to keep  at least  20cm separation with the  antenna while this  end 
product  is  installed  and  operated.  The  end  user  has  to  be  informed  that  the  FCC  radio-frequency  exposure  guidelines  for  an  uncontrolled 
environment  can  be  satisfied.  The  end  user  has  to  also  be  informed  that  any  changes  or  modifications  not  expressly  approved  by  the 
manufacturer could void the user's authority to operate this equipment. If the size of the end product is smaller than 8x10cm, then additional 
FCC part 15.19 statement is required to be available in the users manual: This device complies with Part 15 of FCC rules. Operation is subject to 
the following  two conditions: (1) this  device may  not cause  harmful interference and  (2) this  device must accept any  interference received, 
including interference that may cause undesired operation. 
 

LABEL OF THE END PRODUCT: 

The final end product must be labeled in a visible area with the following " Contains TX FCC ID: TX2-RTL8722DM ". If the size of the end product 
is larger than 8x10cm, then the following FCC part 15.19 statement has to also be available on the label:  This device complies with Part 15 of 
FCC  rules.  Operation is  subject to the following two conditions:  (1) this device may  not cause  harmful  interference and (2) this  device must 
accept any interference received, including interference that may cause undesired operation. 
 

1.6.2

 

Industry Canada Statement 

 
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 
(1) This device may not cause interference; and 
(2) This device must accept any interference, including interference that may cause undesired operation of the device. 

Summary of Contents for RTL8722DM

Page 1: ...formation provided in this document is subject to legal disclaimers REALTEK 2020 All rights reserved 1 RTL8722DM Build and Debug Environment Setup IAR This document illustrates how to build Realtek lo...

Page 2: ...com and a trail version is available for 30 days Note To support ARMv8 M with Security Extension Ameba D HS CPU also called KM4 IAR version must be 8 30 or higher 1 1 2 J Link or RLX Probe If you nee...

Page 3: ...are connected with module by IPEX 1 PCB Onboard Antenna 2 4G peak gain 4 1dbi 5G peak gain 3 9dbi 2 PIFA Antenna 2 4G peak gain 3 5dbi 5G peak gain 5dbi 3 Dipole Antenna 2 4G peak gain 3dbi 5G peak ga...

Page 4: ...spaces are provided to build for each core in project realtek_amebaD_va0_example EWARM RELEASE Project_lp_release eww KM0 workspace contains the following projects km0_bootloader km0_application Proje...

Page 5: ...ct with without TrustZone Project TrustZone Normal Image MP Image km4_bootloader N km4_bootloader is km4_bootloader is Y km4_bootloader tz km4_bootloader tz km4_application N km4_application is km4_ap...

Page 6: ...D Application Note Application Note All information provided in this document is subject to legal disclaimers REALTEK 2020 All rights reserved 6 Fig 1 7 KM0 processor options Fig 1 8 Building KM0 pro...

Page 7: ...the window would disappear automatically 4 After compile the images km0_boot_all bin and km0_image2_all bin can be seen in project realtek_amebaD_va0_example EWARM RELEASE Debug Exe km0_image 1 3 2 2...

Page 8: ...ject When TrustZone is not used there is no need to compile the km4_secure project After building each project IAR will pop up a command prompt window shown in the figure below to execute post build a...

Page 9: ...1 J Link cannot find KM4 As a result if the Flash memory is empty the sequence to download images is 1 Download for km0_bootloader and km0_application projects 2 Click Reset button on demo board to ma...

Page 10: ...ation Note Application Note All information provided in this document is subject to legal disclaimers REALTEK 2020 All rights reserved 10 Fig 1 12 Switching to the target project view Fig 1 13 J Link...

Page 11: ...d put correct value in TCP IP address or hostname as Fig 1 16 shows The value should be localhost port number KM4 The default port numbers is 3333 which is set in project realtek_amebaD_va0_example EW...

Page 12: ...l disclaimers REALTEK 2020 All rights reserved 12 Fig 1 16 RLX Probe interface setup Fig 1 17 RLX Probe window 4 Click Project Download Download active application image downloading starts When downlo...

Page 13: ...u can also erase all parts of the Flash memory if necessary Fig 1 19 Erasing Flash memory 1 3 4 IAR Debug You can debug or trace KM0 and KM4 system individually with J Link or RLX Probe SWD Note Consi...

Page 14: ...ebug without Downloading Download and Debug downloads the application and debug the project object file If necessary a make will be performed before download to ensure the project is up to date Debug...

Page 15: ...et project with IAR by RLX Probe 1 Set the target project as active project and verify the debugger configurations as step 1 and step 3 2 Click Project Attach to Running Target 3 Set the target addres...

Page 16: ...near the cursor in the source window The Toggle Breakpoint button is on the debug toolbar as Fig 1 21 shows 5 You can trace code step by step with Step Into or Go until triggering a breakpoint These...

Page 17: ...document is subject to legal disclaimers REALTEK 2020 All rights reserved 17 Fig 1 24 IAR debug or download error To avoid this error you should build manually before debug or download and disable aut...

Page 18: ...y there are some configurations to put some code into certain memory region In IAR workspace there are PSRAM and SRAM group The code in PSRAM group would be linked and loaded into PSRAM and the code i...

Page 19: ...or ignore secure project project realtek_amebaD_va0_example EWARM RELEASE rtl8721dhp_image2_tz icf for TrustZone project If having a good understand of the format of ICF users can modify the section l...

Page 20: ...ers in IAR project whose version is IAR 8 30 1 or higher You can refer to km4_application map to observe them after project build This file can be found in the following folders Project folder project...

Page 21: ...x17ad7 0x5dfc8 470K bytes memory in SRAM is used The total SRAM space is defined in project realtek_amebaD_va0_example EWARM RELEASE rtl8721d_memory_layout_is icf define symbol __ICFEDIT_region_HS_BD_...

Page 22: ...3 384968 5473 bytes Available heap 56096 bytes Totally free SRAM memory and heap 5473 56096 61569 bytes Totally free PSRAM memory 4 1024 1024 338 1024 A7 3848192 bytes 1 6 warning 1 6 1 Federal Commun...

Page 23: ...ule parts i e FCC transmitter rules listed on the grant and that the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular tr...

Page 24: ...odes r p titifs lorsque cela est requis par la technologie Le dispositif utilis dans la bande 5150 5250 MHz est r serv une utilisation en int rieur afin de r duire le risque de brouillage pr judiciabl...

Page 25: ...pour une utilisation dans un dispositif o l antenne peut tre install e de telle sorte qu une distance de 20cm peut tre maintenue entre l antenne et les utilisateurs Le produit final doit tre tiquet d...

Reviews: