User Manual
12
Table 5 Protection Function Parameters
No.
Items
Function
Function Parameters
Remark
100Ah 100Ah 200Ah 100Ah 200Ah
1
Voltage
Charging
Single cell
charging
over-voltage
protection
3.7V
Release below
3.5V
2
The whole set of
charging
over-voltage
protection
54.45V
58.4V
52.5V/56V
release
3
Discharging
Single cell
discharge low
voltage
protection
2.7V
Release above
3.0V
4
The whole
group of
discharge low
voltage
protection
42.0V
44.8V
Release above
45V
5
Current
Charging
Alarm value
100-105
Delay 5s
protection
6
Over-current
Protection 2
>
110A
Delay 1s
protection
7
Discharging
Over-current
Protection 1
110A
1s delay
8
Over-current
Protection 2
150A
100ms delay
9
Short circuit
protection
Yes
100ms delay
10
Temperature
Cell
Charge and
discharge
temperature
range
Charging temperature range:
﹣
5℃~65℃
Discharge temperature range:
﹣
20℃~70℃
Delay 1s~3s to
confirm
temperature
protection
11
Ambient
Charge and
discharge
temperature
range
Charging temperature range:
﹣
5℃~65℃
Discharge temperature range:
﹣
20℃~70℃
12
PCB
Operating
temperature
range
Below 85℃