Connect the fan power
cable from the appliance
to the termination.
Ensure the cable is
clamped only to the intake
pipe to secure the cable
from hanging loose &
touching the hot flue gases
pipe.
Use the clamp provided.
The clamp can be opened
like a collar and fitted
around on the flue.
Flex collar and fit around the access panel. Socket the
collar all the way up close to the air intake slots Ensure
there is a rubber seal top and bottom of the collar.
Use only the screws provided to tightly fit the collar to seal
the access panel.
Insulation must start as close to the gas space heater as
possible
(Only exhaust flue is to be insulated)
Insulation to be fully closed
and sealed along length.
Fit flue exhaust insulation
Insulated with 25mm foil
faces glasswool pipe
insulation within 0.3m
of each end of flue, as
supplied by Glen Dimplex
Australia.
Bends were practical
should be insulated, by
cutting the insulation into
segments and taping
together.
Joins can be taped
together using aluminum
foil self adhesive tape.
Insulation must be fitted
prior and after the inline
powerflue fan.
Failure to fit insulation on the exhaust flue may result in
condensation failures with the appliance.
Summary of Contents for Element 1200 MARK 2
Page 6: ...6 Page OPERATION INSTRUCTIONS ...
Page 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Page 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Page 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Page 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Page 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Page 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Page 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Page 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Page 81: ...81 Page ...
Page 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Page 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Page 102: ...102 Page ...
Page 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...