U S E R I N S T R U C T I O N S
• Do not operate if you smell gas. Turn appliance off,
extinguish any open flame. Contact your installer or a
licensed gasfitter.
• Do not use if any part of this appliance has been
submerged in water. Contact your installer or a
qualified service technician.
• Solid fuels must not be burnt in the fire. Leaves, sticks,
wood, paper food or material must be kept away
from the fire.
• Should the appliance fail to ignite or was recently
turned off, allow 5 minutes before attempting to
reignite appliance. In the event of abnormal operation
please contact your licensed gas installer, gas
service personnel or Glen Dimplex Pty Ltd. Abnormal
operation may consist of the following, noisy fan,
excessive or small flame, unusual flame appearance
or colour, excessive sooting or other.
APPLIANCE QUICK OPERATION
On/Of f
1. Press power button on the remote.
2. Press mode button until manual appears on lower
area of screen
3. Press arrow up or down to change temperature.
4. Set the desired temperature - it must be above the
room temperature for the appliance to operate.
5. Appliance will start once the flame symbol appears
on the remote.
6. Appliance will perform a 40 second pre-purge, then
sparking will occur.
– Fire should operate within 1 minute of remote calling
for heat.
NOTE –
Should the fire not start, a post purge may
occur, turn off remote - wait 5 minutes before reattempting
to light the fire.
NOTE –
The Element MK2 is fitted with a gas pressure
switch, in the event of no gas, gas supply turned off or low
gas pressure the appliance will not operate.
REMOTE CONTROL GUIDE
The Element MK2 heater is controlled completely by the
use of the remote control; this remote can be used either
as a manual operation or an auto operation.
• The remote thermostat uses radio frequency to transmit
to the gas/fan controller.
• The remote thermostat has a LCD display.
• The remote thermostat uses 2 off “AA” batteries which
should last for 12 months. (Depending on quality of
battery.) Batteries should be changed when smoke
alarms are changed.
• The remote control and the controller are non-
serviceable parts and if faulty should be returned to
Glen Dimplex Pty Ltd for replacement.
LOCATING THE REMOTE
The remote houses the thermostat that controls the heat
output of the fire. When storing the remote either on its wall
bracket or by placing it somewhere in the room where the
fire is located, ensure there are no other heat sources that
will affect the thermostats ability to accurately read the
room temperature. For example, by placing the remote in
direct sunlight or under a cushion, the fire may turn down
or off before the room reaches the set temperature.
Factor y Set Features
• When turned on the fire will always start on the low
setting and remain on low for 3 minutes, it will then go
to the high setting.
• The fan will automatically come on after the fire has
been operating for 3 minutes 20 seconds.
Summary of Contents for Element 1200 MARK 2
Page 6: ...6 Page OPERATION INSTRUCTIONS ...
Page 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Page 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Page 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Page 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Page 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Page 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Page 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Page 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Page 81: ...81 Page ...
Page 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Page 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Page 102: ...102 Page ...
Page 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...