For i4 Flexi, “Ethernet, RS485” and “Wiegand Input or Output” is simultaneous. However, Ethernet
and RS485 are alternatives. If the Ethernet is used, RS485 cannot be used. Likewise, if the RS485 is
used, the Ethernet cannot be used.
Terminal ID:
The machine number ranges from 1 to 999
Baud rate:
The communication speed of the communication with the computer at 19200.
Device IP address:
The default IP is 192.168.0.201. You may modify it according to your
requirements.
Subnet Mask:
The default subnet mask is 255.255.255.0,
Gateway:
The default gateway is 192.168.0.200
Host IP:
The host computer IP to manage the terminal. You may modify it according to your
requirements.
Host Port:
The default port number is 8008. Except for special circumstances, this number should not
be changed.
Mac Address:
Display the MAC address.
Network speed:
The default network speed is 10M, 100M or AUTO detect.
COMM Key:
The System default keyword is none, which is optional to be modified. COM Key is a
security code when communicate with PC software. Connection established when COM key matched.
Wiegand Output:
To assign the Wiegand output type: 26 bit or 34 bit or disable
Wiegand Input:
To assign the Wiegand input mode: Out Door Card or In Door Card
Wiegand Content:
to assign the Wiegand data content: Card Number or User ID.
Warning:
When RS485 communication used in the outdoor environment, the lightning protection
device needs
to be installed.