i4 Flexi is a wall-mounting device.
It is recommended that the device is placed as close as
possible to the door to allow users to open it within the timeout period, which is set at default of
five seconds.
Warning
You have the option to install the device on a table. When installing, choose a
sturdy, level surface in a ventilated area that is dust free and away from heat vents, warm
air exhaust from other devices and direct sunlight. Avoid proximity to large electric
motors or other electromagnetic equipment.
Observe the following guidelines when choosing a good location for the device:
The surface must support at least 2kg
.
Temperature ranges from 32 to 113 degrees F (0 to 45 degrees C).
Humidity should be less than 80%, non-condensing.
Ventilation space should be 2 inches above and on each side, and 5 inches at the rear.
Site should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M)
field strength.
100 to 240 VAC, 50/60Hz power outlet should be within 6 feet of the controller.
V A
u
`
R
E
F
t E
~
Z
H
F
E
G
E
IO
Y
i4 Flexi is delivered without a power supply.
Upon receipt, users must connect the controller to
a DC 12V 3A Power Supply Unit. Communications and DC power are then transmitted via a Cat.
5 cable to the i4 Flexi terminal. Lock power comes from the power supply unit.
Warning
: Do NOT use a separate power supply! Doing so will cause system failure or
hinder operations.
V A
@
K
I
Y
O
J
H
IX
HV
[
E
H
Avoid damage to the surface of i4 Flexi when using a screwdriver to open the cover.
Caution:
Star Key Wrench T10 is required to open the cover.
Notice:
Cable distance for Ethernet Switching
The cable distance between device and hub/PC should not exceed 100 meter.
Cable distance for Device
The cable distance between device and controller should not exceed 50 meter. Using a high
grade cable (individually shield low capacitance pairs), you can increase that distance to as
much as possible with a good grade of cable.
Make sure the wiring is correct
It can be used Category 3/4/5 cable in 10 Mbps operation. To
reliably operate your network at 100Mbps, you must use an Unshielded Twisted-Pair (UTP)
Category 5 cable, or better Data Grade cabling. While a Category 3 or 4 cables may initially
seem to work, it will soon cause data loss. All kinds of hub/PC can connect to i4Flexi by using
straight-through wires.