![Razorweld JRW200AC/DC Operating Manual Download Page 12](http://html.mh-extra.com/html/razorweld/jrw200ac-dc/jrw200ac-dc_operating-manual_792166012.webp)
12
Razor
2OOAC/DC
TIG-ARC
Razorweld
Razor
weld
™
™
™
™
Continued - Weld Program Selection & Setting
Turn the Encoder to set the
Finish Amp value
(Range is 10-200A)
Finish Amp: Select by pushing the encoder knob to
cycle through to illuminate the
Finish Amp icon.
The value selected shows on the digital dis-
play. It is the amount of amps the machine will
deliver at the finish of the welding sequence.
Finish Amp -
Provides selection for the amount of amperage required at the end of the weld.
Turn the Encoder to set
the Down Slope time
(Range is 0-15 Sec)
The value selected shows on the digital
display. It is the amount of time it takes
for the welding amperage to drop down
to the set finish amperage.
Down Slope Time -
Sets the transition time from Welding Amperage to Finish Amperage
Down Slope Time: Select by pushing the
encoder knob to cycle through to illuminate
the Down Slope icon.
Turn the Encoder to set
the Up Slope value
(Range is 0.5-15 Sec)
Post Gas Time: Select by pushing the encoder
knob to cycle through to illuminate the
Gas Timer
Post
icon.
The value selected shows on the digital
display. It is the length of time the gas
will flow after the arc is finished.
Post Gas Timer -
Provides selection for continued gas flow time at the end of the welding after the arc is out.
Turn the Encoder to set
the Up Slope value
(Range is 0-10 Sec)
Up Slope Time: Select by pushing the
encoder to cycle through to illuminate the
Up Slope icon.
The value selected shows on the digital
display. It is the amount of time the
welding current takes to climb from
start amperage to welding amperage.
Up Slope Time -
Sets the transition time from Start Amperage to Welding Amperage
Turn the Encoder to set
the Peak Amp value
(Range is 10-200A)
Peak Amp: Select by pushing the encoder
to cycle through to illuminate the Peak
Amp icon.
The value selected shows on the digital
display. It is the maximum set value of
amperage the machine will deliver.
Peak Amp -
Provides selection for the Maximum Welding Amperage required during welding.
Turn the Encoder to set
the Base Amp value
(Range is 5-200A)
Base Amp: Select by pushing the encoder
to cycle through to illuminate the Base
Amp icon.
The value selected shows on the digital
display. It is the set value of amperage
the machine will deliver during the Base
Amp period of the pulse cycle.
Base Amp -
Provides selection for the Base Amperage during the Pulse Welding cycle.
After selecting finish Amperage you will be prompted to enter "Soft tailout" 0-20ms , after entering finish amperage the finish Amperage light
will stay lit and display 0.0, select your desired tailout from a range of 0-20ms.