63
g
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
37989
SECTION VI
Internal Wiring of Washer
Motor Switch
g
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
AUX.
RED
WHITE
RUN
START
G
Y
BU
BR
W
R
4P M
YELLOW
BROWN
BLUE
YELLOW
OVERLOAD
PROTECTOR
W211SE3A
WHITE
W310SE3A
BROWN
BLUE
YELLOW
RED
R
W
BR
BU
Y
P
Motor Assembly
(1 Speed Motors)