31
Error
number
Reason
Err 5
This is a warning, not an error. One of the parameters is
out of range. The value of the parameter has been
adjusted. For example, sending an
RT
command with a
delay of 0 results in 'Err 5'. The command is accep- ted
but the delay is set to the minimum allowed.
Err 8, Err 12
EEPROM corrupt. The configuration has been cleared.
Err 9, Err 20
Unable to save settings to EEPROM.
Err 27
Unable to read Ethernet settings from EEPROM, so
they may be incorrect.
Err 33
The VTR6 is too hot. The VTR6 has a thermal cut-out
which operates around 65°C to 70°C, depending on
conditions.
Note:
Any other errors are internal errors.
11.4
Event Codes
Event messages are sent when an error occurs. The format of these is:
Evt<channel>,<event code>;
These event messages are only sent after the
GT1
command has been sent.
Event
numb
er
Reason
1 to 127
An error has occurred. The error code is given by the event
number.
130
The temperature of the light is too high and operation
has been stopped.
148
The allowed duty cycle is now normal (after event 149).
149
The allowed duty cycle has been reduced due to high
internal temperature.