Clear any Errors
GR
If Ethernet messages are not enabled, the last event or error number can be
read by this command. If there was a lighting error, the VTR6 resumes
normal operation.
The reply is in the same form as the
GT
command above. If there are no
outstanding events or errors, then only the prompt
>
is returned.
Set/Clear the Webpage Password
EY
EY asc1, asc2, asc3, asc4, asc5, asc6
This command sets the password required to access the webpages. If
EY
is entered on its own, then the password is cleared. There are six optional
parameters, which are decimal ASCII values for a password from one to
six letters. A value of
65 is ‘A’, 66 is ‘B’, and
so on to 90 is
‘Z’.
Report internal temperatures
AT
Each of the three internal LED PCBs has a temperature sensor, and the AT
command reports a string with the following format:
TM 18C 19C 21C [=19C] [.21C19C] 50C 70C
[100%]
In this example:
18C
19C
21C
Reports the measured temperature of the
three LED PCBs.
[=19C]
Reports the average measured temperature of
19°C.
[>21C]
Reports the maximum of the three meas-
ured temperatures.
50C
States the pre-programmed average tem-
perature at which the VTR6 begins to omit
flashes in order to cool down.
70C
States the pre-programmed average tem-
perature at which the VTR6 is omitting all
flashes.
[100%]
Reports the proportion of triggers that the VTR6 is
currently responding to, based upon the average
measured temperature.