19

Fiberglass, aluminum or lightweight steel garage doors 

WILL 

REQUIRE

 reinforcement BEFORE installation of door bracket. 

Contact your door manufacturer for reinforcement kit.

INSTALLATION STEP 11

Fasten the Door Bracket 

Follow instructions which apply to your door type as 
illustrated below or on the following page.

A horizontal reinforcement brace should be long 
enough to be secured to two or three vertical 
supports. A vertical reinforcement brace should cover 
the height of the top panel.

Figure 1 shows one piece of angle iron as the horizontal 
brace. For the vertical brace, 2 pieces of angle iron are 
used to create a U-shaped support. The best solution is to 
check with your garage door manufacturer for an opener 
installation door reinforcement kit.

NOTE: 

Many door reinforcement kits provide for direct 

attachment of the clevis pin and door arm. In this case you 
will not need the door bracket; proceed to Step 12.

SECTIONAL DOORS

1.  Center the door bracket on the previously marked 

vertical centerline used for the header bracket 
installation. Note correct UP placement, as stamped 
inside the bracket.

2.  Position the top edge of the bracket 2"-4" (5-10 cm) 

below the top edge of the door, OR directly below any 
structural support across the top of the door.

3.   Mark, drill holes and install as follows, depending on 

your door’s construction:

Metal or light weight doors using a vertical angle iron 
brace between the door panel support and the door 
bracket: 

•  

Drill 3/16" fastening holes. Secure the door bracket 
using the two 1/4"-14x5/8" self-threading screws
(Figure 2A).

•  

Alternately, use two 5/16" bolts, lock washers and nuts 
(not provided) (Figure 2B).

Metal, insulated or light weight factory reinforced 
doors: 

•  

Drill 3/16" fastening holes. Secure the door bracket 
using the self-threading screws (Figure 3).

Wood Doors:

•  

Use top and bottom or side to side door bracket holes. 
Drill 5/16"

 

holes through the door and secure bracket 

with 5/16"x2" carriage bolts, lock washers and nuts
(not provided) (Figure 4).

NOTE: 

The 1/4"-14x5/8" self-threading screws are not 

intended for use on wood doors.

Vertical
Centerline
of Garage 
Door

Door
Bracket
Location

Header
Bracket

HORIZONTAL AND VERTICAL    
REINFORCEMENT IS NEEDED 
FOR LIGHTWEIGHT GARAGE 
DOORS (FIBERGLASS, 
ALUMINUM, STEEL, DOORS 
WITH GLASS PANEL, ETC.). 
(NOT PROVIDED)

Door
Bracket

Vertical
Centerline 
of Garage Door

UP

Vertical
Reinforcement

Self-Threading
Screw
1/4"-14x5/8"

Self-Threading
Screw
1/4"-14x5/8"

Door
Bracket

Nut
5/16"-18

Bolt
5/16"-18x2"

Lock  Washer
5/16"

UP

Vertical
Reinforcement

(Not Provided)

Vertical
Centerline 
of Garage Door

UP

Self-Threading
Screw
1/4"-14x5/8"

Vertical
Centerline 
of Garage Door

UP

Inside Edge
of Door or
Reinforcement Board

Bolt
5/16"x2"

(Not Provided)

Vertical
Centerline 
of Garage 
Door

Figure 1

Figure 2A

Figure 3

Figure 4

Figure 2B

HARDWARE
SHOWN
ACTUAL SIZE

Summary of Contents for 3255RGD

Page 1: ...l Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and pro...

Page 2: ...r garage door opener 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...your installation Additional materials may be Access Door Safety Reversing Sensor Safety Reversing Sensor Slack in chain tension is normal when garage door is closed Gap between floor and bottom of d...

Page 5: ...ol Visor Clip Door Bracket Multi Function Door Control Panel LOCK LIGHT The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire a...

Page 6: ...nut on the trolley to obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor u...

Page 7: ...e risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener ONLY on properly balanced and lubricated gara...

Page 8: ...the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible...

Page 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Page 10: ...ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join w...

Page 11: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Page 12: ...side of the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a...

Page 13: ...ire in several places Do not pierce wire with a staple creating a short or open circuit 4 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the quick connect terminals as follo...

Page 14: ...hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Sec...

Page 15: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Page 16: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Page 17: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 18: ...lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction...

Page 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...he door if required for your installation Refer to the dotted line optional placement drawing Self Threading Screw 1 4 14x5 8 HARDWARE SHOWN ACTUAL SIZE Header Wall Vertical Centerline of Garage Door...

Page 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Page 22: ...hers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manua...

Page 23: ...as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t...

Page 24: ...ntrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount r...

Page 25: ...bstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY...

Page 26: ...ight feature on the Multi Function Door Control is activated Bulb size is A19 Bulb power is 100 watts maximum SAFETY SIGNALTM light feature Lights will also turn on when someone walks through the open...

Page 27: ...Wall Mounted Door Control THE MULTI FUNCTION DOOR CONTROL Press the push bar to open or close the door Press again to reverse the door during the closing cycle or to stop the door while it s opening...

Page 28: ...or tracks NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the...

Page 29: ...s to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the...

Page 30: ...uch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jump...

Page 31: ...1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish t...

Page 32: ...unit lights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service peop...

Page 33: ...oor control panel 2 371RGD 1 Button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell w...

Page 34: ...s 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block with screws 11 41D3058 Universal replacement motor and bracket assembly Complete with Motor worm bracket bearing assemb...

Page 35: ...ss Entry Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This tem...

Page 36: ...med to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with...

Reviews: