Cable
Part number
Notes
SeaTalk
hs
switch
E55058
8–way hub for network
connection of multiple
SeaTalk
hs
devices.
SeaTalk
hs
coupler
E55060
Coupler for connection
of a single SeaTalk
hs
device.
3.8 VCM100 power connections
VCM100 power and grounding requirements.
The VCM100 is intended for use on ships’ DC power systems
operating from 12 to 24 Volts DC.
• The VCM100 must be connected to a battery isolator switch, or
a DC distribution panel.
• The battery isolator switch or DC distribution panel must be
connected to the POWER IN terminals of the VCM100.
• Do NOT connect additional power switches to the cable providing
the power feed to the VCM100.
• All power connections between the VCM100 and the power
source must have appropriate fuse protection.
• All power connections must be of high quality to minimize
resistance and to remove the risk of accidental shorts.
• The VCM100 SCREEN terminals must be connected to your
vessel’s RF ground system.
• Do NOT connect the radar scanner or the VCM100 to a
positively-grounded power system.
The following diagram illustrates the power connections of the