CAUTION:  Setup requirement

The ST60 Graphic Display is calibrated to factory (default) settings
when first supplied. To ensure optimum performance on your boat, this
product must be setup before use. Do NOT use the product until it has
been setup using

 

the procedures in

Chapter 2, Preparation for Use

.

EMC Installation Guidelines

All Raymarine equipment and accessories are designed to the best industry
standards for use in the recreational marine environment.

Their design and manufacture conforms to the appropriate Electromagnetic
Compatibility (EMC) standards, but correct installation is required to ensure
that performance is not compromised. Although every effort has been taken
to ensure that they will perform under all conditions, it is important to
understand what factors could affect the operation of the product.

The guidelines given here describe the conditions for optimum EMC
performance, but it is recognized that it may not be possible to meet all of
these conditions in all situations. To ensure the best possible conditions for
EMC performance within the constraints imposed by any location, always
ensure the maximum separation possible between different items of
electrical equipment.

For

optimum

EMC performance, it is recommended that

wherever

possible

:

Raymarine equipment and cables connected to it are:

At least 3 ft (1 m) from any equipment transmitting or cables carrying
radio signals e.g. VHF radios, cables and antennas. In the case of SSB
radios, the distance should be increased to 7 ft (2 m).

More than 7 ft (2 m) from the path of a radar beam. A radar beam can
normally be assumed to spread 20 degrees above and below the radi-
ating element.

The equipment is supplied from a separate battery from that used for
engine start. Voltage drops below 10 V in the power supply to our prod-
ucts, and starter motor transients, can cause the equipment to reset. This
will not damage the equipment, but may cause the loss of some informa-
tion and may change the operating mode.

Raymarine specified cables are used. Cutting and rejoining these cables
can compromise EMC performance and must be avoided unless doing so
is detailed in the installation manual.

81228_1.book Page ii Wednesday, November 19, 2003 10:29 AM

Summary of Contents for ST60 Tridata

Page 1: ...ST60 Graphic Display Commissioning Guide Document number 81228 1 Date 1 January 2004...

Page 2: ...Raymarine ST60 and SeaTalk are trademarks of Raymarine Limited Handbook contents copyright Raymarine Limited 2004...

Page 3: ...ription of your ST60 Graphic Display s features and functions Safety notices WARNING Product installation operation This equipment must be installed and operated in accordance with the Raymarine instr...

Page 4: ...sible to meet all of these conditions in all situations To ensure the best possible conditions for EMC performance within the constraints imposed by any location always ensure the maximum separation p...

Page 5: ...pment is to be connected to other equipment using a cable not supplied by Raymarine a suppression ferrite MUST always be attached to the cable near the Raymarine unit Product information To the best o...

Page 6: ...iv ST60 Graphic Display Commissioning Guide...

Page 7: ...and OUT connectors 3 What NMEA data is supported 4 SeaTalk to NMEA 0183 4 NMEA to SeaTalk 4 Alternative uses of NMEA OUT connector 5 Defining the NMEA OUT connector function 5 Chapter 2 Preparation f...

Page 8: ...vi ST60 Graphic Display Commissioning Guide...

Page 9: ...le to provide maximum flexibility when installing your display Optional connections The NMEA IN and NMEA OUT connectors provide a useful means of communicating with external systems but you can carry...

Page 10: ...to a vacant SeaTalk connector on an adjacent instrument You can either break the existing SeaTalk chain to connect as shown in the following illustration or connect to an existing product at the end o...

Page 11: ...ducttootherequipment using a non Raymarine cable you MUST fit an appropriate suppression ferrite to the cable near to the Raymarine product If you want to connect your NMEA IN and NMEA OUT connectors...

Page 12: ...lay The supported NMEA input data is detailed in the following table Data NMEA Header Depth DBT Heading deviation and variation HDG Magnetic heading HDM Water temperature MTW Wind speed and angle MWV...

Page 13: ...NMEA OUT connector to an Auxiliary Alarm you can still use the NMEA IN connector to receive data from NMEA Defining the NMEA OUT connector function Before the ST60 Graphic Display is used you must us...

Page 14: ...6 ST60 Graphic Display Commissioning Guide...

Page 15: ...tput alarm signals to an Auxiliary Alarm If a connection is made to the NMEA OUT connector use the following procedure to define the function 1 Hold down the and buttons for approximately 2 seconds so...

Page 16: ...splay Operation Guide You can Set the Favorite page rollover period or switch the rollover off Switch chapter titles on or off Set whether headings are displayed in true or magnetic form Set the volta...

Page 17: ...Response settings for speed depth heading wind angle wind speed VMG course over ground and speed over ground The correct battery voltage reading Dealer calibration also gives access to A default reset...

Page 18: ...the sensitivity of the display to data changes You can set each response value from 1 to 15 A low number provides a smooth response and a high number a much livelier response Use the button to select...

Page 19: ...em To set the voltage reading at the ST60 Graphic Display 1 With the BATTERY screen displayed measure the 12 V supply voltage at the battery 2 Atthe ST60 Graphic Display usethetrackorresetbutton to se...

Page 20: ...ecommended Depth units Feet Speed units Knots Wind speed units Knots Variation None Alarms All enabled User calibration Enabled Depth response 12 Speed response 12 Heading response 12 Wind angle respo...

Page 21: ...re operational use Basic checks Ensure that the display shows the appropriate chapters and pages as described in the ST60 Graphic Display Operation Guide When doing this be aware that some data types...

Page 22: ...14 ST60 Graphic Display Commissioning Guide...

Page 23: ...setting responses 10 setting voltage reading 11 Default settings 11 E EMC conformance 7 F Factory defaults 11 I Initial checks 13 N NMEA connections 3 NMEA data 4 NMEA OUT setting function 7 uses 5 P...

Page 24: ...16 Index...

Reviews: