background image

ST60 Graphic 
Display

Commissioning 
Guide

Document number: 81228-1
Date: 1 January 2004

81228_1.book Page 1 Wednesday, November 19, 2003 10:29 AM

Summary of Contents for ST60 Tridata

Page 1: ...ST60 Graphic Display Commissioning Guide Document number 81228 1 Date 1 January 2004...

Page 2: ...Raymarine ST60 and SeaTalk are trademarks of Raymarine Limited Handbook contents copyright Raymarine Limited 2004...

Page 3: ...ription of your ST60 Graphic Display s features and functions Safety notices WARNING Product installation operation This equipment must be installed and operated in accordance with the Raymarine instr...

Page 4: ...sible to meet all of these conditions in all situations To ensure the best possible conditions for EMC performance within the constraints imposed by any location always ensure the maximum separation p...

Page 5: ...pment is to be connected to other equipment using a cable not supplied by Raymarine a suppression ferrite MUST always be attached to the cable near the Raymarine unit Product information To the best o...

Page 6: ...iv ST60 Graphic Display Commissioning Guide...

Page 7: ...and OUT connectors 3 What NMEA data is supported 4 SeaTalk to NMEA 0183 4 NMEA to SeaTalk 4 Alternative uses of NMEA OUT connector 5 Defining the NMEA OUT connector function 5 Chapter 2 Preparation f...

Page 8: ...vi ST60 Graphic Display Commissioning Guide...

Page 9: ...le to provide maximum flexibility when installing your display Optional connections The NMEA IN and NMEA OUT connectors provide a useful means of communicating with external systems but you can carry...

Page 10: ...to a vacant SeaTalk connector on an adjacent instrument You can either break the existing SeaTalk chain to connect as shown in the following illustration or connect to an existing product at the end o...

Page 11: ...ducttootherequipment using a non Raymarine cable you MUST fit an appropriate suppression ferrite to the cable near to the Raymarine product If you want to connect your NMEA IN and NMEA OUT connectors...

Page 12: ...lay The supported NMEA input data is detailed in the following table Data NMEA Header Depth DBT Heading deviation and variation HDG Magnetic heading HDM Water temperature MTW Wind speed and angle MWV...

Page 13: ...NMEA OUT connector to an Auxiliary Alarm you can still use the NMEA IN connector to receive data from NMEA Defining the NMEA OUT connector function Before the ST60 Graphic Display is used you must us...

Page 14: ...6 ST60 Graphic Display Commissioning Guide...

Page 15: ...tput alarm signals to an Auxiliary Alarm If a connection is made to the NMEA OUT connector use the following procedure to define the function 1 Hold down the and buttons for approximately 2 seconds so...

Page 16: ...splay Operation Guide You can Set the Favorite page rollover period or switch the rollover off Switch chapter titles on or off Set whether headings are displayed in true or magnetic form Set the volta...

Page 17: ...Response settings for speed depth heading wind angle wind speed VMG course over ground and speed over ground The correct battery voltage reading Dealer calibration also gives access to A default reset...

Page 18: ...the sensitivity of the display to data changes You can set each response value from 1 to 15 A low number provides a smooth response and a high number a much livelier response Use the button to select...

Page 19: ...em To set the voltage reading at the ST60 Graphic Display 1 With the BATTERY screen displayed measure the 12 V supply voltage at the battery 2 Atthe ST60 Graphic Display usethetrackorresetbutton to se...

Page 20: ...ecommended Depth units Feet Speed units Knots Wind speed units Knots Variation None Alarms All enabled User calibration Enabled Depth response 12 Speed response 12 Heading response 12 Wind angle respo...

Page 21: ...re operational use Basic checks Ensure that the display shows the appropriate chapters and pages as described in the ST60 Graphic Display Operation Guide When doing this be aware that some data types...

Page 22: ...14 ST60 Graphic Display Commissioning Guide...

Page 23: ...setting responses 10 setting voltage reading 11 Default settings 11 E EMC conformance 7 F Factory defaults 11 I Initial checks 13 N NMEA connections 3 NMEA data 4 NMEA OUT setting function 7 uses 5 P...

Page 24: ...16 Index...

Reviews: