Battery connection scenario A: suitable for a vessel with a common RF ground point. In
this scenario, if your product’s power cable is supplied with a separate drain wire then it
should be connected to the vessel’s common ground point.
B
Battery connection scenario B: suitable for a vessel without a common grounding point. In
this case, if your product’s power cable is supplied with a separate drain wire then it should
be connected directly to the battery’s negative terminal.
Implementation — connection to distribution panel
• Alternatively, the supplied power cable may be connected to a suitable breaker or switch on the
vessel's distribution panel or factory-fitted power distribution point.
• The distribution point should be fed from the vessel’s primary power source by 8 AWG (8.36 mm
2
)
cable.
• Ideally, all equipment should be wired to individual suitably-rated thermal breakers or fuses, with
appropriate circuit protection. Where this is not possible and more than 1 item of equipment shares
a breaker, use individual in-line fuses for each power circuit to provide the necessary protection.
52
Summary of Contents for Ray 90
Page 2: ......
Page 4: ......
Page 44: ...44...
Page 92: ...92...
Page 127: ...Menu Description Options Flybridge Mast Group 1 to Group 5 VHF operations 127...
Page 128: ...128...
Page 134: ...134...
Page 135: ...Chapter 10 Maintenance Chapter contents 10 1 Maintenance on page 136 Maintenance 135...
Page 152: ...152...
Page 164: ...164...
Page 190: ......
Page 191: ......