Chapter 7: Setting Up the System Defaults
7-13
B
earin
g Alig
nm
en
t
To change the range scale, highlight the required range and use the soft
keys to change the value. Start at the top of the list and work down, since
each value must be greater than the value for the previous range in the list.
The following scale increments are available:
When you have finished setting up the new scale, press
ENTER
to return to
the Radar Set Up Menu, and press the
ON
soft key to select your new
scale.
Bearing Alignment
The bearing alignment is normally set when you first install your system,
and is described in
Radar System Checks and Adjustments
on
page 8-17
.
The bearing alignment corrects for display azimuth error. It can be set to a
value in the range -180° to +179.5°, in increments of 0.5°.
Antenna Size
This option is used to specify the size of an open array scanner. Refer to
the Pathfinder Scanner Owner’s handbook for further details.
Send on HSB
SEND ON HSB
can be used to stop radar data being transmitted on
hsb
2
.
If
SEND ON HSB is set to OFF
, you can view your radar data on the master
display, but not on a repeater display.
Table 7-4:
Radar Range Scale Increments
Range Scales (nm)
Scale Increments (nm)
0.125 to 0.5
0.125
0.5 to 3.0
0.25
3.0 to 6.0
0.5
6.0 to 24.0
2.0
24 to maximum for scanner
4.0
Summary of Contents for hsb2 PLUS Series
Page 4: ......
Page 16: ...xiv hsb2 PLUS Series Color LCD Display...
Page 70: ...2 34 hsb2 PLUS Series Color LCD Display Displaying the Radar and Synchronizing Radar Chart...
Page 158: ...6 12 hsb2 PLUS Series Color LCD Display Data Log Mode...
Page 210: ...8 32 hsb2 PLUS Series Color LCD Display Transmitted Data...
Page 232: ...C 6 hsb2 PLUS Series Color LCD Display C MAP Chart Card Features...