Chapter 2: Installation
43
Pump Cable
Cable Length
(Distribution Panel to
Pump)
Cable Gauge
Copper Area
Up to 3m (10ft)
8 AWG
6 mm
Up to 7m (22ft)
6 AWG
10 mm
Up to 16m (52ft)
4 AWG
16 mm
81004-07
Solenoid Cable
Solenoid Cable Length
(Course Computer to Pump)
Cable Gauge
Copper Area
Up to 7m (23ft)
12 AWG
2.5 mm
Up to 12m (39ft)
10 AWG
4.0 mm
Up to 17m (55ft)
8 AWG
6.0 mm
81004-08
An isolator switch should be installed in the power supply to the complete
system.
The solenoid valve connectors can only accept cable up to 12 AWG. If
larger cable is required, 18 inches of 12 AWG should be used to wire to
the connectors.
The Type CR Interface may also be connected to alternative constant
running hydraulic pump providing:
• the solenoid coils take less than 10 amps
• the response time of the solenoid valve is less than 80 milliseconds
• the operating voltage of the solenoid coils is the same as the course
computer supply voltage.
It is important to minimise the overall cable length between the pump and
the vessels power distribution panel.