Chapter 2: Installation
35
2.6 Hydraulic Drive Systems
This section covers the installation of hydraulic system components
together with relevant plumbing and cabling procedures.
For optimum autopilot performance it is important that the pump specifica-
tions given below match the vessel's steering ram.
Pump to Cylinder Specifications
Pump
Capacity
Type 1
80 to 230cc (4.9 to 14cu in)
Type 2
160 to 350cc (9.8 to 21cu in)
Type 3
250 to 460cc (15 to 28cu in)
CR1
350 to 500cc (21 to 30cu in)
CR2
500 to 1200cc (30 to 73cu in)
81004-04
Reversing Hydraulic Pumps (Type 1, Type 2 & Type 3)
Mounting
The hydraulic pump should be mounted in a horizontal position clear of
spray and possible water immersion. It should also be located as near as
possible to the hydraulic steering cylinder.
Bolt the hydraulic pump to a substantial member to avoid vibration that
could damage the interconnecting pipework.
Cabling
Using a suitably sized cable (see below) route the pump leads back to the
course computer and connect to the motor terminals.
Type 1 Drive Unit
Cable Length (Drive Unit
to Course Computer)
Cable Gauge
Copper Area
Up to 3m (10ft)
12 AWG
2.5 mm
Up to 5m (16ft)
10 AWG
4 mm
Up to 7m (23ft)
8 AWG
6 mm
Up to 10m (32ft)
6 AWG
10 mm
Up to 16m (52ft)
4 AWG
16 mm
81004-05
Summary of Contents for Autohelm 100
Page 2: ...AUTOPILOT Installation and Set Up TYPE 100 300 ...
Page 3: ......
Page 101: ...TYPE100 300OperationandInstallationHandbook 100 ...
Page 103: ...TYPE100 300OperationandInstallationHandbook 102 ...
Page 108: ......
Page 109: ...NautechLimited AnchoragePark Portsmouth P035TD England Telephone 0705 693611 Fax 0705 694642 ...