6 Battery storage and recharging
6.1 Battery storage requirements
1. Storage environment requirements:
–ambient temperature: -10
℃
...
45
℃
; recommended storage temperature: 20
℃
...30
℃
;
–relative humidity: 0% 90%RH;
...
–in a dry, ventilated and clean place;
–no contact with corrosive organic solvents, gases and other substances;
–no direct sunlight;
–less than 2 meters from any heat source.
6.2 Storage expiration
In principle, it is not recommended to store the battery for a long time. Be sure to use it in time. The stored
batteries should be disposed according to the following requirements.
Table 6.2 Stored lithium battery recharging interval
1
.
If a battery is deformed, broken or leaking, discard it immediately regardless of its storage time.
2
.
The allowable maximum stored battery recharging period is 3 years and the allowable maximum stored
battery recharging times is 3. For example, if recharging is performed once every 8 months, the allowable
maximum recharging times is 3 times; if recharging is performed once every 12 months, the allowable
maximum recharging times is 3 times; if the allowable maximum stored battery recharging period or times is
exceeded, it is recommended to discard the battery.
3
.
A lithium battery will have its capacity decreasing after being stored for a long time, and typically will have
its capacity irreversibly decreasing by 3%–10% after being stored at the recommended storage temperature
for 12 months. If the customer conducts the discharge test and acceptance according to the specifica
tion,
there is a risk that the battery with a capacity less than 100% after being stored will fail the test.
6.3 Inspection before battery recharging
Before recharging a battery, check its appearance: Deformation/Shell damage/Leakage
Required Storage Temperature
Actual Storage
Temperature
Recharge Interval
-10
℃
...
+45
℃
-10
℃
≤
T
≤
30
℃
12 months
30
℃<
T
≤
45
℃
8 months