2.6 Liability Limitation
Any product damage or property loss caused by the following conditions, Rayleigh Instruments does not
assume any direct or indirect liability.
•
Product modified, the design changed or parts replaced without
Rayleigh Instruments authorization;
•
Changes, repair attempts and erasing of seri number or seals by
al
unqualified personnel;
•
System design and installation are not in compliance with standards and regulations; Fail to comply
with the local safety regulations;
•
Transport damage (including painting scratch caused by rubbing inside packaging during shipping). A
claim should be made directly to the shipping or insurance company in this case as soon as the
container/packaging is unloaded and such damage is identified;
•
Fail
to follow any/all of the user manual, the installation guide and the maintenance regulations;
ure
•
Improper use or misuse of the device;
•
Insufficient ventilation
the device;
for
•
The maintenance procedures relating to the product have not been followed to an acceptable standard;
Force majeure (violent or stormy weather, lightning, overvoltage, fire etc.); Damages caused by any
external factors.
3.Installation
Please be cautious unpacking the battery, otherwise, components could be damaged.
3.1 Installation Environment
3.1.1 General
RI-ENERGYFLOW-MODULAR energy storage system is an outdoor version and can be installed in an
outdoor or indoor location. When RI-ENERGYFLOW-MODULAR systems are installed in a room, RI-
ENERGYFLOW-MODULAR must not be hampered by the structure of the building, the furnishings and
equipment of the room. The Inverter is naturally ventilated. The location should therefore be clean, dry and
adequately ventilated. The mounting location must allow free access to the unit for installation and
maintenance purposes, and the system panels must not be blocked. The following locations are not allowed
for installation:
•
Habitable rooms;
•
Ceiling cavities or wall cavities;
•
On roofs that are not specifically considered suitable;
•
Access/exit areas or under stairs/access walkways;
•
Locations with humidity and condensation over 90%;
•
Places where salty and humid air can penetrate;
•
Seismic areas - additional security measures are required;
•
Sites with altitude
2000m;
above
•
Places with an explosive atmosphere;
•
Locations with direct sunlight or a large change in the ambient temperature;
•
Places with flammable materials or gases or an explosive atmosphere.
Page 18