Please follow below figure to
assemble DRM connector
Figure 13 DRM connector
3.5 Single Line Diagram
The single line diagrams of DC-, AC- and Hybrid-coupled systems are as below:
Figure 14 DC-coupled system
Telephone : +44 (0) 1245 428500
Email : [email protected]
Page 29
3.4 DRED Port Connections (Optional)
DRED means demand response enable device. The AS/NZS 4777.2:2015 required inverter need to support
demand response mode (DRM). This function is for the inverter that complies with AS/NZS 4777.2:2015
standard. RI-ENERGYFLOW-MODULAR single-phase inverter fully complies with all DRM. A 6P terminal is
used for DRM connection.
Pin
Description
Pin
Description
1
DRM 1/5
4
DRM 4/8
2
DRM 2/6
5
RefGen
3
DRM 3/7
6
Com/DRMO