Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW150/1500
21
applied to the pins 17-9 of the DB-25 interface connector under the assumption that emission has
been enabled before.
The details of the main control functions in all modes and sub-modes of operation are listed
in Table 6.
Table 6 The main control functions
Emission Enabling
Hardware Emission Control Enabled
1
Hardware Emission Control Disabled
Control interface
(DB-25 – pin7-9)
RS-232 or Ethernet
Power Setting
Analog Power Control Enabled
2
Analog Power Control disabled
Control interface
(DB-25 – pin8-9)
RS-232 or Ethernet
Guide Laser
Enabling
External Aiming Beam Control Enabled
3
External Aiming Beam Control disabled
Control interface
(DB-25 – pin21-9)
RS-232 or Ethernet
Reset Errors
RS-232 or Ethernet or Analog Interface
Available Operation
Modes
CW, Pulsed
Available Operation
Sub-Modes
Standalone, Modulation, Gate
Operation Mode
Selection
RS-232 or Ethernet
1: To enable HARDWARE EMISSION CONTROL send the command “ELE” via RS-232 or Ethernet interface, to disable -
“DLE.”
2: To enable ANALOG POWER CONTROL send the command “EEC” via RS-232or Ethernet interface, to disable - “DEC.”
3: To enable EXTERNAL AIMING BEAM CONTROL send the command “EEABC” via RS-232 or Ethernet interface, to
disable - “DEABC.”
Wave mode
The Raycus software can reads a waveform file from the memory if a waveform has been
edited and stored before (See Appendix 1.6 “Waveform Editing” for more information about
how to edit and store a waveform). And the output power for the laser varies with the
waveform(power curve).The emission starts/stops is performed by means of the modulation
signal applied to the pins 17-9 of the DB-25 interface connector under the assumption that
emission has been enable before.