Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3300W~RFL-C15000W
14
(5) Check the output head and clean it before installation. This procedure must
be performed by Raycus personnel or person authorized by Raycus.
(6) Prevent the delivery cable from treading, pinching or excessive bending
during installation.
(7) Make sure the environment is clean, or the output head may be
contaminated. It is prohibited to use fan during installation, which will
cause dust in the air.
(8) The minimum bending radius of the transmission cable of the laser shall
not be less than 20cm in the non-working state (such as transport and
storage). The minimum bending radius should not be less than 30cm when
the laser is work.
(9) Users can employ four lifting rings or rollers on the top or bottom of the
device to carry or move it, as shown in figure8 (please check whether the
lifting rings are installed firmly and whether the rollers are fully mobile
before transporting the device).
(10)
a) Lifting ring (taking 4kW as an
example).
(10)
b) Leveling casters (taking 6kW as an example).
Figure 7 Laser top lifting ring and bottom level adjustment caster.
Leveling caster
Leveling caster
Lifting ring
Lifting ring