45
STA
Bit 15
No laser
Send: ‘STA’
Return: ‘STA:4100’
returned value 4100(Decimal) can
be converted to 0 x1004
(hexadecimal), and then converted
to binary to see that Bits2 and 12
have been set.The laser enable is on
and the modulation mode is enabled
Laser is power on
Bit 16
Gate mode=off
Gate mode=on
Bit 17
AC input normal
AC input abnormal
Bit 18
External Emission control=off
External Emission control=on
Bit 19
Normal
Laser fault
Bit 20
Slow up slow down mode off
Slow up slow down mode on
Bit 21
A laser operates in ON" mode
A laser operates in REM" mode
Bit 22
Wave mode off
Wave mode on
Bit 23
Surge protector Normal
Surge protector failure
Bit 24
Normal
Low temperature fault
Bit 25
Normal
Humidity alarm
Bit 26
Normal
Water flowmeter 1 Flow Alarm
Bit 27
Red light internal control
Red Light External Control
Bit 28
Normal
Water flowmeter 2 Flow Alarm
Bit 29
Normal
Module locked
Bit 30
Optical circuit safety interlock normal
Optical circuit safety interlock abnormal
Bit 31
Normal
High average power