can still use window hyper terminal to monitor the laser, in this condition, you must connect
‘RS-232’ to your computer.
4.9.2 The Operation in AD Mode
Before you start the laser, check the wiring, cooling connection and the most important, the
delivery cable and optic terminal are OK. Make sure that the interlock is shorted, and the laser
emission button is up (emission disabled). Then start the chiller.
Turn the key to ‘REM’ position to start the laser, and system start self-check. If the interlock is
not shorted or the ‘LASER’ button is pressed down, the system self-check cannot pass. In this
condition, you must power off the laser, and deal with the problem, then start the laser again.
The system self-check will pass in about 30 seconds, after that, the laser is ready to receive
analog signal, and you can press down ‘LASER’ button to enable the laser emission.
In AD mode, the laser emits on conditions that ‘LASER’ button is pressed down, analog signal is
received and remote modulation signal inputs from ‘MOD’.
You can still use hyper terminal to monitor the status of the laser. All you have to do is to start
windows hyper terminal, and configure it as stated in 4.7.2 Hyper Terminal Setup. But you can’t
set operation parameters from hyper terminal when the control mode is AD.
CAUTION
:
Please ensure that the analog signal DOES NOT exceed 10V, or
product may be damaged.
4.10 The control of pilot laser
Turn the key to ‘REM’ or ’ON’ position to start the laser, and the system start. The POWER
indicator lights up, the pilot laser lights up simultaneously. After you press down the LASER
button , the pilot laser lights out.