Press ‘3’ in the mode selection page to enter ‘CW mode with remote modulation’, and press ‘4’
to enter ‘Pulse mode with remote modulation’. In these 2 operation modes, the parameter
settings are no different from ‘CW mode’ and ‘Pulse mode’. Only one more emission condition
is added-remote modulation signal. So you must connect ‘MOD’ to remote modulation signal
with the MOD cable we provided. Notice that the modulation signal is 24V level, and active
high.
When the parameters are set, laser emission is enabled (‘LASER’ on front panel is pressed
down), and the remote modulation signal inputs from ‘MOD’, the laser emits.
Clear errors
Press ‘5’ in the mode selection page will clear error records. Then press ‘7’ to return.
Error records are cleared
Press ‘7’ to return to previous menu
Save system configurations
This operation is for Raycus personnel only.
4.8 RS-232 Mode
RS-232 mode is a remote control mode. In this mode, we have a protocol for communication
between the laser and the upper computer, and you can set emission parameters and return
errors. Notice that the 'LASER' button is of no use in this mode, but make sure to keep it up.