Wuhan Raycus Fiber Laser Technologies Co., Ltd.
Fiber Delivered Direct Diode Laser User Guide 1500W
31
When the percentage of output power is set and laser emission is enabled (‘LASER’ on front
panel is pressed down), the laser emits. ‘MOD’ on the rear panel is left disconnected in this
mode.
You can press ‘Enter’ again to set another value for percentage of power, or press ‘7’ to return
to previous menu to choose another operation mode.
Pulse mode
Press ‘2’ in the mode selection page, you will enter ‘Pulse mode’. You should provide 3
parameters for this operation-repetition frequency, duty cycle and percentage of output
power.
For example, set the repetition frequency to 2kHz, duty cycle to 50% and percentage of output
power to 60%.
The present operation mode is pulse mode
Please set repetition frequency (MIN=50, MAX=50000), press ‘Enter’ to confirm: 2000
Please set duty cycle (MIN=0, MAX=100), press ‘Enter’ to confirm: 50
Please set percentage of output (MIN=0, MAX=100), press ‘Enter’ to confirm:60
Press ‘7’ to return to previous menu, press ‘Enter’ to reset
The repetition frequency is between 50Hz and 50kHz, but you must input a number between 50
and 50000, so for 2kHz, input 2000;
Duty cycle is between 0% and 100%, for 50%, type in 50;
For 60% output power, type in 60;
If you input a value out of the range specified in the brackets, the system will instruct you again
to input a legal value. Just follow the instructions.
When the parameters are set and laser emission is enabled (‘LASER’ on front panel is pressed
down), the laser emits sequence of pulses you have customized. ‘MOD’ on the rear panel is also
left disconnected in this mode.
CW mode with remote modulation and Pulse mode with remote modulation