14
In floor sensing mode, the user sees the room temperature
Floor temperature
[Installer menu n°1]
– Offset
[Installer menu n°2]
= Room temperature (seen on the thermostat)
The thermostat has an ‘OFF mode’. In this stand-by mode,
the floor heating is not powered at all. The thermostat
screen will display the actual measured room temperature.
In the summer time, in this 'OFF mode', the thermostat acts
as a thermometer only.
To go to the ‘OFF mode’ press simultaneously the
<
> keys for more than 1 second. Repeat this step to
exit this mode.
The off mode is available only after the end of the first
warming function and after the learning function. When one
of these functions is in progress the thermostat can power
up the floor warming system even if the thermostat is in off
mode.
4.3 Installer's menu
If the desired temperature is not reached or if there is a
difference between real floor/room temperature and the set
value on the display, calibrate the thermostat.
Push and hold OK button for 6 seconds to enter following
Menu:
°
c
°
c
Normal mode
OFF mode
5s after
OFF mode with
tempertaure view
Pressed simultaneously
for more than 1s
To come back to
normal mode