The appliance is floor mounted. The space in which the
appliance is to be fitted must have the following minimum
dimensions.
Between wall or unit and LH side of appliance - 10mm
top plate
Between wall or unit and RH side of appliance - 10mm
top plate
SHOULD THE WALL PROJECT BEYOND THE FRONT
OF THE APPLIANCE, THEN THE GAP AT THE R.H.
SIDE MUST BE INCREASED TO 50mm. TO ALLOW
DOOR TO OPEN ENOUGH TO CHANGE OVEN AND
SHELF POSITIONS, (SEE FIG. 1).
Above the raised insulating cover handle - 60mm
In addition adequate clearance must be available at the
front of the appliance to enable it to be operated and
serviced.
The appliance is delivered in a fully assembled condition
with the exception of the following items which are
supplied separately packed and require assembly:-
The appliance rear distance bracket
The cooker handrail
FLUE PIPE KIT
Flue pipe comprises of:-
3 x 1 metre of flue pipe
3 elbows
3 straight couplers
6 support brackets (saddle and clamps)
1 tube ultra-grey sealant
Pack of fastenings
Additional lengths of pipes and fittings are available as
optional extras including a 45° angle bend.
Appliance rear distance bracket: If the rear wall is of
combustible material, there must be an air gap of 25mm
between the wall and the rear of the cooker. Fit the rear
distance brackets as shown in Fig. 15. Wherever possible
it is recommended that the skirting board is removed for
the width of the appliance to enable the rear edge of the
appliance top plate to make contact with the vertical wall
and avoid a rear gap. (Combustible wall excepted).
Where the cooker is to stand in a recess or against a wall
which is to be tiled,
UNDER NO CIRCUMSTANCES
SHOULD THE TILES OVERLAP THE TOP PLATE.
Installation requirements
13
CLEARANCES
PRELIMINARY INSTALLATION
FIG. 15
DESN 514122
Summary of Contents for XT
Page 20: ...20 Wiring Diagram FIG 21 WIRING DIAGRAM APPLIANCE ...
Page 22: ...22 ...
Page 23: ...23 ...