background image

10

Fig. 8

Summary of Contents for 200 G

Page 1: ...E APPLIANCE 1 01 10 EINS 510974 raywarranty aga web co uk INTRODUCTION INSTALLATION INSTRUCTIONS Technical Specification Natural Gas Heat Input 5 6kW Pressure G20 20mbar G25 25mbar Injector Size 1 82 Bray 460 Pilot Size 38 36A LP Heat Input 6 3kW Nominal Rate G31 Propane 489 g h G30 Butane 497 g h Inlet Pressure G31 Propane 37mbar G30 Butane 28mbar Injector Size 1 27 Bray 220 Pilot Size 4209 Consu...

Page 2: ... A flue pipe constructed in a to c should form the initial connection to lined chimneys Where a chimney is to be used which is not composed of or lined with a non porous acid resistant material it should be lined with a stainless steel flexible flue liner The internal diameter of the liner must be not less than 100mm and the number of joints must be kept to a minimum If the flue liner is not to be...

Page 3: ...grammer is available which will provide a timing feature to switch the main oven to the desired temperature setting as and when required See Fig 3 13m3 h of fresh air is required 60m3 h of fresh air is required THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH REGULATIONS IN FORCE General The appliance is floor mounted and must have the following minimum clearances for servicing installation Bet...

Page 4: ...g care not to damage the enamelled painted components of the floor covering in the room and insert suitable rollers beneath the base plate to aid positioning of the appliance When in position remove rollers and continue assembly NOTE IF THE REAR WALL IS OF COMBUSTIBLE MATERIAL THERE MUST BE AN AIR GAP OF 25mm BETWEEN THE WALL AND REAR OF APPLIANCE FIT REAR DISTANCE BRACKET AS SHOWN IN FIG 5 2 Asse...

Page 5: ...is in line with pipework 5 Turn the control knob B to the ignition symbol and depress it fully 6 Keeping control knob B depressed fully simultaneously press Piezo Spark Generator C repeatedly until the pilot flame lights This is visible through the sight glass F Fig 7 A few seconds must be allowed for the gas to reach the pilot burner 7 Continue to hold down Control Knob B for at least 15 seconds ...

Page 6: ...6 Fig 7 ...

Page 7: ...ow cooking load or idling conditions and the thermostat set to give the appropriate oven conditions when cooking see the Rayburn Cook Book for recipes The cooker burner provides heat for two ovens and hotplate A main gas service cock is incorporated below the cooker burner control valve Operation The burner K has a permanent pilot light H protected by a flame supervision valve Turning ON the main ...

Page 8: ...lean Heat Exchanger and Flueways a Replace the main and pilot burner assembly as previously described b Place a layer of paper on combustion chamber baseplate c Examine insulation panels for any sign of deterioration replace if necessary d Remove layer of paper with fallen debris e Check that oven top is free of deposit and brush in between ribs on hotplate underside f Examine soft rope seal locat...

Page 9: ...ufficiently to enable the phial to be removed from its clips push the phial towards the rear of the oven to release it from the front bracket j The thermostat can now be removed k Straighten an equivalent length of capillary on the new thermostat taking care when doing so not to kink it l Feed the capillary back through the front tube into the oven and relocate the capillary in the support bracket...

Page 10: ...10 Fig 8 ...

Page 11: ...11 ...

Page 12: ...licy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by AGA Station Road Ketley Telford Shropshire TF1 5AQ England www rayburn web co uk www agacookshop co uk www agalinks com ...

Reviews: