If there is any type of extract fan fitted in the same room
as an appliance, there is a possibility that if adequate air
inlet area from outside is not provided, spillage of the
products from the appliance flue could occur when the
extract fan is in operation.
Where such installations occur, a spillage test must be
carried out as follows:- By holding a smoke match so that
the flame is approximately 3mm up inside the lower edge
of the draught diverter. Spillage is indicated by the smoke
being displaced outwards from the draught diverter.
Any necessary remedial action must then be taken.
Wiring external to the appliance must be installed in
accordance with the current Wiring Regulations and any
local regulations which apply. The appliance is supplied
for 230V ~ 50Hz and fuse rating of 3A.
The method of connection to the mains electricity supply
must facilitate complete electrical isolation of the
appliance, preferably by the use of an unswitched
shuttered socket outlet in conjunction with a fused three-
pin plug.
Alternatively, a fused double-pole switch having contact
separation of at least 3mm in both poles serving only the
appliance may be used.
The point of connection to the mains should be readily
accessible and adjacent to the appliance. For wiring
instructions See Fig. 2.
An optional external electrical programmer is available,
which will provide a timing feature to switch the main oven
to the desired temperature setting as and when required.
See Fig. 3.
13m
3
/h of fresh air is required.
60m
3
/h of fresh air is required.
THIS APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH REGULATIONS IN FORCE.
General
The appliance is floor-mounted and must have the
following minimum clearances for servicing/installation:-
Between wall and LH side of appliance 150mm
Between wall and RH side of appliance 25mm
Above the raised insulating cover handle 60mm
Where the cooker is to stand in a recess or against a wall
which is to be tiled,
in no circumstances should the
tiles overlap the cooker top plate.
In addition, adequate clearance must be available at the
front of the appliance to enable it to be operated and
serviced. Flue piping and fittings must not be closer than
25mm to combustible materials and where passing
through a combustible partition such as a ceiling or roof,
must be enclosed in non-combustible sleeve providing an
air space of at least 25mm.
Spaces around flue pipes passing through walls or floors
should be sealed against the passage of smoke and
flame.
INSTALLATION OF APPLIANCE
COMBUSTION AIR SUPPLY
VENTILATION
3
ELECTRICAL SUPPLY
CONTROLS
EFFECT OF AN EXTRACTION FAN
Fig. 2 Wiring diagram without programmer
Fig. 3 Wiring diagram with programmer
COOKER STAT.
COOKER STAT.
SOLENOID
SOLENOID
MAINS INPUT
(FUSED 3 AMP)
MAINS INPUT
(FUSED 3 AMP)
E P PROGRAMMER
MOUNTING PANEL
KEY
G/Y -
GREEN/YELLOW
BL -
BLUE
BR -
BROWN
CDSD
CDSD
LINK