Company Confidential
15
Raveon Technologies Corp.
QCLR
Remove all WMX frames from the WMX frame queue.
None
-
SHOW
Show/display an overview of the radio’s configuration.
None
-
WMX
Read/set the WMX serial port protocol. 0=off, 1= enabled.
0, 1
0
WMXVR
Read the WMX version
None
WMXINFO
Read WMX information.
Returns:
Aa, bb, ccc, dd
where
AA = Number of WMX message buffers in the product’s WMX
queue.
bb = Number of WMX messaged queued
up in the product’s
WMX frame queue.
ccd = Total size of WMX message buffers in bytes.
dd = WMX version implemented in the product.
** indicates values that are calibrated in the factory and are unit-specific. If the “Radio
Type” is changed, these will need to be re-calibrated.
5.2.
Data Modem Mode Related Commands
These commands apply to the operation of the M8S when it is in the data
modem communication mode.
Command
Command Description
Parameters
Factory
Default
ATBC
Busy Channel Lock Out
– Enable/disable the BCL. If enabled,
the modem will not transmit on a radio channel that is busy (has
RF on if). 0-OFF, 1=ON.
Range: 0-1
0
AT
DT
Destination Address to call
– Sets address of the modem to
send data to. Note, this parameter is entered in HEX format.
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or an F.
Range: 0-FFFF
1234
AT
HS
Show History
– Show a table of listing the most recent
receptions, and the IDs that the data was sent from. The time
shown is time in seconds since the reception, 2mS resolution.
No parameter
AT
HX
Enable/Disable single-hop repeating
–
0=any number of
repeats, 1
– unit will not repeat a packet that was already
repeated.
0 or 1
0 (multi-hop
OK)
AT
LA
Listen Address
– Configures the listen address for this unit. The
unit will receive data if this listen address matches the destination
address in a data transmission. FFFF to disable it.
Range: 0000 - FFFF
1234
AT
MK
Address Mask
– Configures local and global address space.
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or F. In most
applications, this is kept at FFFF.
Range: 0000 - FFFF
FFFF
AT
MY
Unit Address
– Configures the individual; address for this unit.
Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or F. Note: FF
is interpreted as a group. See addressing section.
Range: 0000 - FFFF
1234
AT
PE
Packet Error Display –
Shows statistics to compute packet-
error rate. Displays Packets Per Minute (PPM) and a running
total.
None (display PER)
1 = reset counters
2 = Stop PER display
None
AT
PO
RF Power Output
. Set or show the RF power output setting.
Value is in percent, from 0% to 100%. Use and RF wattmeter to
confirm the power setting, and adjust the % accordingly to obtain
the desired RF power level.
0-100
100
AT
R0
Symbol Peak Deviation
– Set the peak FM deviation of the
transmit symbols. Note: This can be a negative number to invert
the modulation.
Range: -1000 – 1000
120**