Company Confidential
11
Raveon Technologies Corp.
exposing the two circuit boards. The button is in the front edge of the radio
module’s circuit board.
The default settings that the modem will revert to when the CONFIG button is
pressed are:
1. Serial port 9600 baud, 8 data bits 1 stop, no parity
2. ATCT setting set to 60000 (60 second time-out)
3. Serial port on the front of the unit in RS232 mode, 9600bps, N/8/1.
Even though the serial baud rate reverts to 9600 baud when the CONFIG
button is pressed and the IO port is RS232, it will revert back to the settings
programmed into the
M8S
modem once the Command Mode is exited.
4.6. Exiting the Command Mode
There are three ways to exit the command mode. They are:
1.
ATCN
Issuing the
ATCN
. The M8S radio will exit the command mode,
and begin normal operation.
2.
EXIT
Issuing the
EXIT
. The M8S radio will exit the command mode, and
begin normal operation.
3.
Time Out
. After a pre-set amount of time (60 seconds is the factory
default time), the modem will automatically exit the Command Mode, and
continue normal operation. Changes will not automatically be saved. This
time-out duration may be set with the
ATCT