45
11.2
INSTALLATION INSTRUCTIONS FOR CONCENTRIC 80/125 FLUE SYSTEM
L + L = 23.5m Max
Straight Flue Straight Flue 90° Offset Flue 135° Offset Flue
L = 25 m Max L = 25 m Max L = 21.0 m Max L = 22.5 m Max
plus Terminal plus Terminal plus Terminal plus Terminal
11.2.1
The vertical 80/125flue kit is intended for use
where a horizontal 60/100
flue outlet is not possible or desired.
The vertical flue can be used either with
a flat roof or a pitched roof (maximum pitch 60°).
Where a straight vertical flue is not possible or
desired, an offset vertical flue can be used in
conjunction with a side horizontal flue extension
piece and an inline 135°/90° flue bend (Fig. 99).
Part No Description
0019PRO11030/0 Flue Extension 80/125 L1000
0019PRO11025/0 Flue Extension 80/125 L500
0019RID11005/0 125/80 to 100/60 Flue reducer
0019CUR11025/0 45° Flue bend 80/125
0019CUR11030/0 90° Flue bend 80/125
0019TER01005/0 Horizontal Flue Terminal 80/125
0019TER11010/0 Vertical Flue Terminal 80/125
0019TEG06005/0 Flashing sleave
IMPORTANT:
- See Fig. 98 and 99 for terminal clearances.
- The pressure loss see table 6.
Fig. 99
IMPORTANT NOTICE:
- When using our vertical fl ue kit the 125mm x 100 reducer is
supplied complete with the vertical terminal simply remove this
and fi x it into the fl ue adaptor on the top of the boiler
Fig. 98
Available on request from:
RAVENHEAT MANUFACTURING LTD
Chartist Way,Morley, Leeds, West Yorkshire
ENGLAND LS27 9ET - U.K.
Tel. 0044(0) 113 252 7007
NOTE :
If using Flue arrangement in Fig.99 then the 125x100 Flue reducer
must be purchased separately