Plume Management Kit
Maximum Length (mm) 6000
minimum length (mm) 500
Equivalent length of 45° bend (mm) 500
Equivalent length of 90° bend (mm) 1000
IMPORTANT : Max fl ue length must not exceed
6 m with a horizontal concentric
60/100 fl ue of 3m ( L )
Fig. 15
The Maximum permitted fl ue length is
measured from the centre line of the
fl ue terminal to the top of the outlet
terminal
PLUME MANAGEMENT KIT (Fig 15)
Max 6000 mm fl ue extension duct as an extra cost only
when requested to reduce pluming nuisance of condensation from
60/100 horizontal concentric fl ue.
IMPORTANT :Please, lubricate the
internal part of the seals before
being fitted.
19
OPTIONAL EXTRAS:
Part. No Description
0019PRO11005/0 Flue Extension 60/100 L500
0019PRO11010/0 Flue Extension 60/100 L1000
0019CUR11005/0 45° Elbow bend 60/100
0019CUR11010/0 90° Elbow bend 60/100
0019TER11005/0 Horizontal terminal 60/100
0019GRI11015/0 Horizontal terminal header 60/100
0019TER06010/0 Vertical fl ue Terminal
ACCESSORIES CONCENTRIC FLUE 60/100 EXTRAS:
TABLE 7
Plume Management Kit Part No
Part. No Description
0019PRO11035/0 Flue Extension 60 L1000 Plume
0019CUR11035/0 90° Elbow bend 60 Plume
0019CUR11040/0 45° Elbow bend 60 Plume
0019TER11025/0 Horizontal terminal 60/100 Plume
0019GRI11020/0 Horizontal elbow header 60 Plume