![Ravenheat HE 120N Instructions For Use Installation And Servicingtion And Servicing Download Page 21](http://html1.mh-extra.com/html/ravenheat/he-120n/he-120n_instructions-for-use-installation-and-servicingtion-and-servicing_3856514021.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
INTAKE AND EXHAUST TERMINAL COMPONENTS
Fig.31
20
IMPORTANT :Please, lubricate the
internal part of the seals before
being fitted.
KEY
56 - Flue adapter
58 - Header gasket
59 - Rubber seal Ø 60
61 - STD fl ue exhaust duct
62 - Terminal
63 - Flue extension
64 - Flue exhaust duct extension
65 - Flue manifold rubber seal
66 - Securing screw
67 - Sample point
127 - Terminal Rubber wall seal
128 - Elbow header
Fig 30
Fig.32
5.5.10
IN LINE FLUE BEND
Measure the distance between the flue bends or
the flue/terminal assembly. The measurements
should be taken from the outer edge of the flue
and bend (Fig. 39B).
IMPORTANT:
inline flue bend - 1000 mm
must be deducted from overall length for each
90°bend. Obtuse flue bend - 500 mm must be
deducted from overall length for each 135°
bend (Table 6).
5.6
COMPLETING BOILER INSTALLATION
5.6.1
Reassemble the outer casing (sect 5.4) in
reverse order.
Fig.31a