VSN® System Settings and Tuning: System Settings Tab
35
VSN® SYSTEM SETTINGS AND TUNING
ADVANCED SETTINGS
To access advanced VSN system settings:
1. From the VSN home page, select the Tools button.
2. Select the System Settings tab.
3. Select the Advanced Settings button. The following settings and options will be displayed.
FIGURE 6. Advanced Settings Page
Filter Level.
This setting controls the noise level in the guidance errors sent onto the CANbus from VSN. A lower
setting has less filtering and lower latency. A higher setting has more filtering and more latency.
NOTE:
The default value for the Filter Level is 2. It is only recommended to adjust this setting with the
support of a technician.
Row Guidance Optimization.
Select either curved or straight for optimal steering performance in the typical rows
in your fields.
Quality Warning Offset.
The threshold above the Row Detection Quality (shown on Home page) at which the
operator will be notified that the solution quality from the VSN system has dropped to into a caution state. This
value is editable.
For example, if the Row Detection Quality is set to 50 and the Quality Warning Offset is set to 10, the VSN icon will
be in a caution (yellow) state when the Row Detection Quality is between 50 and 60.
Side Hill Compensation.
Provides additional compensation to adjust for guidance errors due to machine roll.
NOTE:
The Side Hill Compensation feature is enabled by default and is recommended for most machine
operations.
System
Settings
Advanced
Settings
Tools
Summary of Contents for VSN
Page 1: ...Copyright 2019 2020 2021 2022 VSN Operation Manual 016 2020 001 Rev E 8 2022 E42804 ...
Page 8: ...CHAPTER 1 4 VSN Operation Manual ...
Page 14: ...CHAPTER 2 10 VSN Operation Manual ...
Page 34: ...CHAPTER 4 30 VSN Operation Manual ...
Page 50: ...CHAPTER 6 46 VSN Operation Manual FIGURE 8 Software Installation in Progress ...