40
1)
Flush carrier system with water after use of suspension type products. Failure to clean systems
can result in crystallization of products which may plug the Flow Meter, lines, and/or tips.
2)
Flush and drain system before storing.
IMPORTANT: Freezing temperatures may damage system if water is not drained.
3)
Periodically clean strainer on Injection Module.
4)
Check oil level in Injection Pump daily. If addition of oil is required, add Mobil #1 (5W30) ONLY.
Drain and refill the pump after every 150 hours of operation. (See Figure 14).
5)
Flush Injection system by using flush system (See "RECOMMENDED INJECTION PUMP
FLUSH SYSTEM") or by recirculating water through Injection Module until pump is clear of
product. When storing at the end of season, recirculate antifreeze during the last flush.
FIGURE 14