13
VERIFYING FLOW RATE LIMITS:
The gallons per minute (GPM) (liter per minute [lit/min]) flow rate of the sprayer must be within the
range of that specified for the Flow Meter included with the Console.
FLOW METER MODEL
FLOW RANGE
RFM 5
0.05-5 GPM [0.2-18.9 lit/min]
RFM 15
0.3-15 GPM [1.1-56.8 lit/min]
RFM 60P/60S
1-60 GPM [3.8-227 lit/min]
RFM 100
3-100 GPM [11.4-379 lit/min]
RFM 200/200 Poly
15-200 GPM [56.8-757 lit/min]
RFM 400
25-400 GPM [94.6-1514 lit/min]
2)
Determine the target application rate for PROD 2 CAL that you are spraying (Refer to the instructions
on the product container) using section DETERMINING INJECTION MODULE METER CAL.
FIGURE 8