36
TU (TURF UNITS)
Speed
=
15
Boom Width
=
36 nozzles x 20 inches = 720 inches
Rate
=
.73 oz/1,000 sq. ft.
Maximum oz/min
=
15 MPH x 720 inches x .73 oz/1,000 sq. ft. = 58.1
137
EXAMPLE: Minimum vol/min (High Volume Pump)
US (ENGLISH UNITS)
Speed
=
8 MPH
Boom Width
=
12 nozzles x 20 inches/nozzle = 240 inches
Rate
=
2 pints/acre x 16 oz/pint = 32 oz/acre
oz/min
=
8 MPH x 240 inches x 32 oz/acre = 10.3
5,940
SI (METRIC UNITS)
Speed
=
12.9 km/h
Boom Width
=
12 nozzles x 51 cm/nozzles = 612 cm
Rate
=
2.3 lit/ha x 10 dl/liter = 23 dl/ha
dl/min
=
12.9 km/h x 612 cm x 23 dl/ha = 3.0
60,000
TU (TURF UNITS)
Speed
=
8
Boom Width
=
12 nozzles x 20 inches = 240 inches
Rate
=
.73 oz/1,000 sq. ft.
oz/min
=
8 MPH x 240 inches x .73 oz/1,000 sq. ft. = 10.3
137
2)
Locate the calculated MAXIMUM and MINIMUM oz/min [dl/min] on the horizontal line of Pump
Chart. (See Figures 12A, 12B & 12C).
3)
Draw a vertical line from these points to the highest pump setting.
4)
Use highest pump setting which intersects both vertical lines on the graphs.
EXAMPLE:
MAXIMUM setting of 58.1 oz/min [17.0 dl/min]; MINIMUM setting of
10.3 oz/min [3.0 dl/min] = pump setting 6 (See Figure 13).
NOTE:Use the "10" setting for all product application rates that are within the range of the
"10" setting (i.e. 2.5 to 200 oz/min for the high volume module, 1.0 to 100 oz/min for
the low volume module and .5 to 40 oz/min for the ultra low volume module.)
NOTE:The pump must be set to the "10" setting for priming.
5.
ADJUSTING PUMP SETTING
1)
Loosen the pump-setting locking nut, pull out on locking pin and rotate the 2-10 setting pointer
to the proper number. (See Figure 13).
2)
Tighten the pump setting locking nut taking care to keep setting pointer on the number.