17
b)
Depress
.
8)
To display the volume/minute being applied
a)
Depress
for 5 seconds.
9)
To display current VALVE CAL setting
a)
Depress
for 5 seconds. VALVE CAL number will show in DATA
display.
10)
To view any of the set calibration numbers, depress the corresponding calibration
keys.
3.
SELF TEST FEATURE
SELF TEST allows speed simulation for testing the system while the vehicle is
not moving. Enter the simulated operating speed by depressing
for 5
seconds. Display will show "-tESt-". If 6 MPH [9.6 km/h] is desired, enter
6.0 [9.6] (See CONSOLE PROGRAMMING). Verify SPEED by depressing
.
The
display will show 6.0 [9.6]. The SELF TEST speed will clear itself when
motion of vehicle is detected by the Speed Sensor. A SPEED CAL value of 900
[230] or greater is recommended when operating in this mode.
NOTE:
To prevent nuisance clearing of self-test speed, disconnect speed
connector on back of the Console when Radar Speed Sensors are used.
4.
ALARM MENU
1)
To display ALARM MENU
a)
Depress
for 5 seconds. "A on" will show in the DATA display.
b)
Momentarily depressing
toggles the display between "A on" and
"A off".
"A on" means alarm is enabled, "A off" means alarm is disabled.
5.
OFF TARGET ALARM
Alarm sounds when the actual rate is off from the target rate by a specified
percentage. The Off Target value is preset to 30%, but may be changed to a different
number.
1)
Adjusting Off Target value.